Installation Manual of Room Air Conditioner

Drawing for the installation of indoor and outdoor units

The models adopt HFC free refrigerant R410A

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Screw

Plastic cap

Drain-elbow

Cushion

1

1

A

B

C

D

E

F

G

2

3

4

5

6

7

2

1

1

4

1

4

Number
    of
articles

Accessory parts

Optional parts for piping

Mark

Parts name

more than 5cm

more than 10cm

more than 60cm

more than 15cm

Non-adhesive tape

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be
more than 2m.

more than 10cm

more than 10cm

more than 10cm

Adhesive tape

Saddle(L.S) with screws

Attention must be paid to
the rising up of drain hose

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

4X25

Piping hole cover

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
     soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

Necessary Tools for Installation

Содержание HSU-09HSA103

Страница 1: ...een the indoor unit and the floor should be more than 2m more than 10cm more than 10cm more than 10cm Adhesive tape Saddle L S with screws Attention must be paid to the rising up of drain hose Arrange...

Страница 2: ...by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to...

Страница 3: ...by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape Find the level...

Страница 4: ...h heat insulation materials closely and make sure fixing with adhesive tape Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper...

Страница 5: ...number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufactu...

Страница 6: ...professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant Half u...

Страница 7: ...leakage No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valv...

Страница 8: ...rried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drain...

Отзывы: