Indoor unit

3.Installation of the Indoor Unit

4.Connecting the indoor/outdoor Electric Cable

Drawing of pipe

Fixing the indoor unit body

Removing the wiring cover

Rear piping

Left Left-rear piping

Other direction piping

Draw pipes and the drain hose, then fasten them with the adhesive tape

In case of left side piping, cut away, with a nipper, the lid for left piping.

In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear

piping which is marked on heat insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then

    connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

    Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape

Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.

Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according

to the position of wall hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation

of connecting part specially.

Hang surely the unit body onto the upper notches of the

mounting plate. Move the body from side to side to verify

its secure fixing.

In order to fix the body onto the mounting plate,hold up

the body aslant from the underside and then put it down

perpendicularly.

Remove terminal cover at right bottom corner of indoor unit, then

take off wiring cover by removing its screws.

Lid for right piping

Lid for under piping pipe

Lid for left piping

Heat insulation
material

Drain hose

Piping

Indoor/outdoor
electric cable

Fix with adhesive tape

4

Содержание HSU-09HSA103

Страница 1: ...een the indoor unit and the floor should be more than 2m more than 10cm more than 10cm more than 10cm Adhesive tape Saddle L S with screws Attention must be paid to the rising up of drain hose Arrange...

Страница 2: ...by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to...

Страница 3: ...by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape Find the level...

Страница 4: ...h heat insulation materials closely and make sure fixing with adhesive tape Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper...

Страница 5: ...number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufactu...

Страница 6: ...professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant Half u...

Страница 7: ...leakage No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valv...

Страница 8: ...rried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drain...

Отзывы: