background image

Indoor unit

When connecting the cable after installing the indoor unit

When connecting the cable before installing the indoor unit

1. Insert from outside the room cable into left side of the wall hole, in which
    the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.

Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
       is not correct, proper operation can not be carried out and will cause defect.
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
   qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
    distance between its two contacts should be not less than 3mm.

5

1(N)

2(L)

3(C)

1(N)

2(L)

3(C)

L

N

Indoor unit

Outdoor unit

HSU-22HSA03/R2(DB)

POWER PLUG

HSU-18HSA03/R2(DB)

Indoor unit

Outdoor unit

HSU-09HSA03/R2(DB)
HSU-12HSA03/R2(DB)

1(N)

2(L)

3(C)

1(N)

2(L)

3(C)

HSU-09HSA103/R2(DB)
HSU-12HSA103/R2(DB)

Connecting wiring :

Содержание HSU-09HSA103

Страница 1: ...een the indoor unit and the floor should be more than 2m more than 10cm more than 10cm more than 10cm Adhesive tape Saddle L S with screws Attention must be paid to the rising up of drain hose Arrange...

Страница 2: ...by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to...

Страница 3: ...by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape Find the level...

Страница 4: ...h heat insulation materials closely and make sure fixing with adhesive tape Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper...

Страница 5: ...number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufactu...

Страница 6: ...professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant Half u...

Страница 7: ...leakage No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valv...

Страница 8: ...rried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drain...

Отзывы: