Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
43/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Service step
Maintenance
Cleaning
works
Daily
At least once
quarterly
At least once
or twice a
year
but
Every
1000 h
At least once
yearly
but
Every
2000 h
PLEASE NOTE:
Whenever any electrical components are disconnected and reconnected,
replaced or repaired, a safety test must be conducted, at least on these
components!!!
8. Machine housing and built-in components
Check machine housing, tank, sheet metal body, door, sub-structure
cladding, entry and discharge sections for watertightness
Maschinengehäuse, Tank, Blechaufbau, Tür
Unterbauverkleidungen auf ZerFaulten und Vollständigkeit prüfen
Tankabdecksieb auf Vollständigkeit, ZerFault, richtige Position und
richtigen Sitz überprüfen
Spritzschutzvorhänge auf Vollständigkeit und richtige Position prüfen
Schottbleche auf Vollständigkeit und richtige Position prüfen
Check door guide rails
Check door roller springs (exchange all even if only one is defective)
Check electrical door control switch function
Check door control switch for mechanical damage
9. Equipment area
Checks on operating temperature and water consumption
Measure tank water temperatures (x2), rinse water temperatures (x3) and
compare with values in the documentation
x2, x3
x1
see later
Heating system
Check the complete system for watertightness
Clean dirt trap
Check function of the valves
Clean water system
Check the complete system for watertightness
Clean dirt trap
Check function of the valves
Clean level control
Check level control function
Check water supply quality – water hardness (according to the installation
plan)
Check machine and all components for lime-scale deposits.
Descale, if
necessary
Check water supply quality – conductivity x5 for demineralised water or
reverse osmosis water
Check water supply quality – temperatures (according to the installation
plan)
x5
see later