Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
37/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
14
Tips for self-help in the case of faults
Fault:
Remedy
Machine does not fill.
•
No water available
•
Dirt trap blocked
•
Level electrode / float valve soiled
•
Solenoid valve defective
Rinse water does not
spray!
•
No water available
•
Dirt trap blocked
•
Solenoid valve defective
•
Fresh water rinse system furred
Vapours drains!
•
Extraction broke down
•
Curtains missing
•
Temperatures too high
•
Seperation panels not completely inserted.
•
Wash arms, drying nozzles, air guide plates bent or
not correctly inserted
Stripes and smears on the
tray
•
Rinse water mineral content too high (see operating
instructions)
•
Different water type depending on the waterworks
•
Unsuitable rinse aid products or wrong dosage
quantity
•
Incorrectly fitted or missing curtains
Formation of a significant
amount of foam in the
wash tank!
•
Rinse water quantity too low
•
Temperatures too low < 40°C
•
Detergent or rinse aid product not suitable
Tray not clean after
washing!
•
Wash pump not running
•
Spray nozzles clogged or wrongly fitted
•
Wash arms mixed up
•
Pump suction sieve clogged
•
Cleaning agent concentration too low or unsuitable
•
Temperatures too low
•
Marked foaming
Tray is not drying!
•
Fan motor failed
•
Rinse aid concentration too low or not suitable
•
Plastic material as new
•
Vapour suction quantity too low
STB has triggered!
•
The
reason
for its action
must be found and
eliminated.
(In particular, the condition of the heater
must be checked). The temperature safety limit switch
may only be re-set after the defect has been rectified
and the heating system has cooled down.
Содержание BTA160