Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
40/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
20
Maintenance recommendation
Service step
Maintenance
Cleaning
works
Daily
At least once
quarterly
At least once
or twice a
year
but
Every
1000 h
At least once
yearly
but
Every
2000 h
PLEASE NOTE:
Whenever any electrical components are disconnected and reconnected,
replaced or repaired, a safety test must be conducted, at least on these
components!!!!!!
Tip:
„Exchange the wearing parts designated „V“ from the spare parts list.!“
1. General cleaning
Screen basket
Tank cover screen
Pump suction side sieves
Spray protection curtains
Wash- and rinse arm jets
Wash tanks
Float valve housing of the water level monitoring
1. Drive
Check drive motor
Check drive motor for exterior damage
Check drive motor for quiet running
Check current consumption (IN see wiring diagram)
Check ventilation grid for cleanliness
Check drive chain
Check chain wheels, chain and chain adjuster for wear and tear
Check chain adjuster function
Check chain tension
Regrease chain if necessary (spray-on penetrating oil or silicone spray)
Check conveyor limit switch for correct disconnection
Check switch for electrical function
Check limit switch for mechanical damage
Check limit switch function with regard to the lag (the distance the
conveyor runs after being switched off). The mechanical contact travel of
the limit switch rocker must be greater than the conveyor lag.
Check the shaft bearings