C
ONFIGURE
& I
NSTALL
B
OARD
2-8
C
P
C
I
N
o
S
w
it
ch
es
CPCI
No Switches
There are no switches on the CPCI. Because the CPCI complies with the PCI Plug-and-Play
specification, the BIOS
automatically sets
the I/O addresses and IRQ of all peripherals in the
system.
Accessing the CPCI
In order to properly access the controller using any MEI-supplied utility ( Motion Console) or
your own application program, you must obtain the address the BIOS gave to the CPCI-bus
computer (at start-up). This can be determined by an MEI supplied function,
find_pci_dsp(...),
or via Motion Console.
Motion Console will automatically find all PCI controllers on the bus. Simply select
Add Con-
troller
and click on the
PCI Controller
tab. The address and IRQ of all PCI bus controllers will
be listed.
Usage of the MEI function
find_pci_dsp(...)
is further described in the
C Programming Refer-
ence Manual.
Please refer to that document for a detailed description on using this function.
If you are still having problems communicating with the controller after you’ve found its ad-
dress, you may have to reserve the resources in use by the controller using the
System
applet in
the control panel.
Connect Cables/Insert Board
To install the controller:
1.
Turn off the power to your computer
.
STC-26
CBL-26
STC-20
CBL-20
STC-50
CBL-50
CPCI
Connect CPCI to STCs
3 Cables
3 STCs
4 STCs
4 Cables