SG32-UG-EN-V01 Dec 2016
55
3
OPERATION OF THE MTDR100
On the SG32-1500M ensure the rotary Voltage Control knob (item 12) is set to
the "Zero Start" position.
Unless using HV methods of Pre-location the Voltage Range switch (item 14)
can be set to any range. If using HV methods of Pre-location this Voltage Range
switch (item 14) is to be set to the desired range either 16 or 32kV.
The Select Mode switch (item 16) is set to the TDR, Arc Reflection Group.
To select
TDR Mode
: Depress the TDR mode Pushbutton switch (item
18).
To select
Arc Reflection Mode
: Depress the Arc Reflection mode
pushbutton (item 20).
NOTE:
The selected mode pushbuttons will illuminate.