SG32-UG-EN-V01 Dec 2016
1
1
SPECIFICATIONS
Supply
Input Voltage source
SG32-1500M-xx is fitted with a universal input power supply and as such
can be supplied from 108-265V AC Power supplies.
2 each fuses, 12A slow blow, for 120V operation are installed
if operated from 230V please install 2 each 6A slow blow fuses provided in
the accessory bag
The SG32-1500M-xx, maximum power requirement is 1200 VA when used
with AC input. Two-pole three-terminal grounding type connector must be
used.
Modes of Operation
High Voltage
Hipot / Proof / Burn, Surge Impulse (Thump), Arc Reflection ,
Arc Reflection (Multi-shot), Differential Arc Reflection (DART) , ICE
Low Voltage
TDR / Pulse Echo ; Direct; Comparison
HIGH VOLTAGE
Output voltage
0 to 16 kV DC
0 to 32 kV DC
Proof Current
0 to 40 mA (16 kV range)
0 to 20 mA (32 kV range)
Burn Current
0 to 40 mA (16 kV range)
0 to 20 mA (32 kV range)