16
Suggested Order of Installation
For ease of installation, it is recommended that the system components be installed in the following order:
1. Position and mount the head unit (the manifold should be positioned between 1-3mm above the web).
2. Position and mount the Air Handling Unit (in free air to avoid overheating and considering the available ducting
lengths).
3. Make all the electrical connections.
4. Make all compressed air connections (if required).
5. Connect all ducting and secure using clips.
Mounting the CyClean-R
Positioning of the System
The CyClean-R head unit is installed over the apex of a guide roller and can be positioned at any angle without
jeopardising cleaning performance .
In general, the CyClean-R system should be installed as close to the critical process as possible to minimise the
potential of re-contaminating the web via airborne contamination. Meech would recommend between 1-3mm over
the web; however, this may differ depending on the application.
Where a double-sided configuration is required the CyClean-R heads will be installed at different stages of the web.
Web Direction and Tension
Due to the way the CyClean-R has been designed; web tension is not relevant due to the positioning over the roller.
The CyClean-R should only be mounted in the orientation it was designed. See figure 5 below showing the pip on
the CyClean-R extrusion.