P11 EXP
Portable Digital Color Doppler Ultrasound System
1-
13
For maximum safety, adhere to these guidelines:
• Proper grounding of the system is critical to avoid electrical shock. For protec-
tion, ground the system with a three-conductor cable, and plug the system
into a hospital-grade receptacle or outlet.
• Do not remove or entangle the grounding wire.
• Do not remove the protective covers of the system. These covers protect
users from hazardous voltages. Only authorized service technicians can make
replacements of the parts inside the system.
• Never use this system while inflammable gas is present!
• Devices must be powered from the receptacles marked “hospital grade” or
“hospital only” before being connected to the system directly. In case where
“hospital grade” receptacles are not available, use isolation transformers in-
stead.
• Operators and patient must not contact any exposed metal terminals of the
plugs.
• Duration of continuous physical contact with any applied parts of this ultra-
sound system must not exceed 4 hours.
1.10
Cautions for Using Accessories
• Any accessories, provided by other manufacturers other than the manufacturer,
to be connected either electrically or mechanically to this ultrasound system must
comply with the specified IEC standards (IEC 60950 Information Technology
Equipment - Safety and IEC 60601-1 Medical electrical equipment Part 1: General
requirements for basic safety and essential performance.)
• For cleaning, disinfection and sterilization of accessories, please follow the instruc-
tions provided by the manufacturers.
• Installation and service of accessories shall be performed according to the require-
ments of the manufacturers.
• Disposal of the accessories at the end of the product life shall follow the guidance of
the manufacturers.
• The accessories provided with the ultrasound system, e.g. the foot switch and the
printer, are safe to operate in patient environment. Other accessories or devices not
listed in the list of supported accessories must not be used. You may contact us for
the updated version of the list.
• Contact with natural rubber latex may cause a severe anaphylactic reaction in persons
sensitive to the natural latex protein. The operator and patients must avoid contact
with these items. Refer to package labeling to determine latex content and
FDA’s
March 29, 1991 Medical Alert on latex products.
1.11
Environmental Protection
In order to protect the environment, the disposal of waste products, residues, etc. and of the
ultrasound system and accessories at the end of their expected service life should follow
these guidelines:
Содержание P11 EXP
Страница 1: ...User Manual P11 EXP Ultrasound System Version 1 1 ...
Страница 4: ...P11 EXP Portable Digital Color Doppler Ultrasound System 0 2 ...
Страница 56: ...P11 EXP Portable Digital Color Doppler Ultrasound System 4 4 6 5 Annotation Edit Figure 4 11 Annotation edit ...
Страница 80: ...P11 EXP Portable Digital Color Doppler Ultrasound System 5 16 ...
Страница 102: ...8 8 P11 EXP Portable Digital Color Doppler Ultrasound System ...
Страница 118: ...P11 EXP Portable Digital Color Doppler Ultrasound System 10 10 ...
Страница 126: ...P11 EXP Portable Digital Color Doppler Ultrasound System 12 6 ...
Страница 136: ...P11 EXP Portable Digital Color Doppler Ultrasound System 13 ...
Страница 146: ...P11 EXP Portable Digital Color Doppler Ultrasound System A 6 ...
Страница 148: ...B 2 P11 EXP Portable Digital Color Doppler Ultrasound System ...