Warranty & return policy

Safety warnings

8.2

8.3

8

Troubleshooting & technical information

The Manufacturer’s Warranty states that products are warranted to be free from defects in material and workmanship 

for a defined period. The Manufacturer’s sole obligation in the event of a breach of this warranty is expressly limited to 

the replacement of defective parts that, in the sole discretion of the Manufacturer, cannot be repaired. Replacement 

parts may be new or refurbished parts as solely determined by the Manufacturer. This warranty is available only to the 

original user and is not transferable. Repairs or alterations to the product not conducted by the Manufacturer shall void 

these warranties. These warranties do not cover failures due to improper or negligent use of the product. The Pressure 

Control Unit (PCU) is covered by warranty for 3 years. The garments are covered by warranty for 1 year. 

For questions regarding the Manufacturer’s Warranty and technical support, please contact:

Medi USA, LP

6481 Franz Warner Parkway

Whitsett, NC 27377

(800)633.6334

[email protected] 

Warning:

 Explosion Hazard

Do not use in the presence of flammable gases, including flammable anesthetics.

Warning:

 Electrical Shock Hazard

Do not allow liquid to enter any part of the system.

Warning: 

Electric Shock Hazard

Never attempt to perform maintenance or service the device while in use. To completely eliminate power, 

disconnect the power supply from the Pressure Control Unit or from the wall outlet.

Warning:

Electric Shock Hazard

Unplug power supply from source and do not use medi pcs during electrical storms.

Warning:

 Electric Shock Hazard

To prevent electric shock, do not open the Pressure Control Unit. Do not attempt to service the pressure control 

unit yourself.  All maintenance tasks should be performed only by the manufacturer or by authorized service 

personnel.  Service by unauthorized personnel shall void the warranty.

Warning: 

Ventilation Hazards

Always place the pump on a solid surface free of objects that may block ventilation openings.  Never lock the 

ventilation openings.  Keep the ventilation opening free of debris such as lint and hair.  Never operate the pump on 

a soft surface, such as a bed, couch, or pillow, where the ventilation opening may be blocked.  Never drop or insert 

any object into any opening of the pump.

Warning:

 Environmental Hazards

Keep the pump, garments, and power supply cord and plug away from sharp objects, flames, and heated surfaces.

Warning:

 Proper Inspection Required

Prior to using always inspect pressure control unit, power supply, garments, and connectors for damage.

Warning:

 Tripping

Never operate the controller where the cord or tubing harness shall present a tripping hazard.

Warning:

 Strangulation

The power supply and hoses of this product may pose a strangulation hazard. Keep power supply and hoses out of 

the reach of children at all times.

Содержание Pcs brio

Страница 1: ...medi pcsbrio medi pcs brio pneumatic compression system Operator s Manual...

Страница 2: ...2...

Страница 3: ...session 6 4 Turning off the PCU 6 5 Error screen 7 1 Storing the medi pcs brio 7 2 Cleaning the medi pcs brio 8 1 Troubleshooting 8 2 Warranty return policy 8 3 Safety warnings precautions 8 4 Labels...

Страница 4: ...stingpulmonary edema existingpulmonaryembolism inflammatoryphlebitis severecongestivecardiacfailure severeatherosclerosisor otherischemicvasculardiseases anycircumstancewhere increasedvenousandlymphat...

Страница 5: ...ression garment sizing and application information 4 Power Supply The power supply 2 1 4 connects the PCU to an electrical outlet Step 1 When your medi pcs brio arrives carefully unpack the contents a...

Страница 6: ...he garment going up the garment from distal to proximal The step value setting can be changed in 1 mmHg increments ranging from 1 60 mmHg However the step value range is limited such that no chamber w...

Страница 7: ...distal pressure is set to 50 mmHg with a step value of 3 mmHg Chamber 1 2 3 4 5 6 mmHg 50 47 44 41 38 35 Example 2 An 8 chamber garment whole leg or arm where the distal pressure is set to 80 mmHg wit...

Страница 8: ...e medi pcs brio is now ready to operate Please review the settings displayed in the Treatment Summary screen to ensure that all settings have been entered correctly If you must unlock or change the tr...

Страница 9: ..._____________________________ Language ______________________________ Treatment time ____________________________ Distal pressure ______________________________ Access level __________________________...

Страница 10: ...cm Lower Leg Sizing Measurements T i p o f M i d d l e F i n g e r t o A x i l l a C G Floor to Knee Crease B C Floor to Gluteal Fold C G B Arm Garment Sizing Measurements Size Item Leg Length Circumf...

Страница 11: ...before applying If desired apply a liner over the limb before applying the garment This will help keep the garment clean during use Loose unrestrictive clothing such as sweatpants or cotton t shirts m...

Страница 12: ...arment either slide your limb out of the garment or undo the hook and loop material and remove your limb It is recommended to keep the hook and loop material fastened even when the compression garment...

Страница 13: ...e latch mechanism and pulling the connector out The blocking port can remain in place for future treatment sessions Step 1 Locate the garment connectors at the end of the hoses attached to the garment...

Страница 14: ...appear 6 4 The PCU will begin the fill to fit process after which the programmed treatment cycle will begin The Treatment Running screen will show treatment time remaining current active chamber in us...

Страница 15: ...t Summary Screen Press the power switch on the back of the PCU to turn off the medi pcs brio Please note that the PCU inflation deflation valves close while the PCU is turned off If a garment is conne...

Страница 16: ...sure that the power supply is unplugged before cleaning the PCU Gently wipe the PCU with a slightly damp cloth Do not allow any moisture or liquid to enter the device If additional cleaning is require...

Страница 17: ...d any rapid movements or drastic posture changes during the first 5 10 minutes of treatment 2 Verify that the correct treatment settings have been selected by referring to the Treatment Summary screen...

Страница 18: ...e or service the device while in use To completely eliminate power disconnect the power supply from the Pressure Control Unit or from the wall outlet Warning Electric Shock Hazard Unplug power supply...

Страница 19: ...nce pain or notice your condition worsening contact your physician Do not change your treatment settings without consulting your physician Warning Parental Supervision Children under the age of 18 sho...

Страница 20: ...ing the safety requirements specified for Class II equipment according to IEC 61140 Non ionizing electro magnetic radiation ISO 7000 IEC 60417 Graphical symbols for use on equipment 5140 To indicate o...

Страница 21: ...47 Part15 Subpart B ICES 001 ISSUE 4 AS NZS CISPR 11 JIS T 0601 1 2 ABNT NBR IEC 60601 1 2 LEGAL MANUFACTURER medi USA LP 6481 Franz Warner Parkway Whitsett NC 27377 www mediusa com Made in USA Tempe...

Страница 22: ...perating normally WARNING Use of accessories transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or...

Страница 23: ...cle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles h Single phase at 0 0 UT 250 300 cycle 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles...

Страница 24: ...ncy range b Interference may occur in the vicinity of equipment marked with the following symbol Guidance and Manufacturer s Declaration Electromagnetic Immunity NOTE 1 At 80 MHz and 800 MHz the highe...

Страница 25: ...o any part of the medi pcs including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance E 6 d P...

Страница 26: ...nd mobile RF communications equipment transmitters and the medi pcs as recommended below according to the maximum output power of the communications equipment For transmitters rated at a maximum outpu...

Страница 27: ...27 For other language translations please visit www mediusa com...

Страница 28: ...medi USA 6481 Franz Warner Parkway Whitsett NC 27377 info mediusa com T 800 633 6334 F 888 570 4554 mediusa com PBO157 Rev A...

Отзывы: