6-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction is prohibited
AUTOMATIC MODE WITH AUTO-ECO
This mode changes product operation to
automatic
: when the user-set temperature is reached, the product switches to power 1
for a brief amount of time and then, if the temperature stays stable and higher than the set value, it switches off. The appliance only
automatically switches back on when the room/water request more heat (not before the required product cooling period). This option is
only recommended if the product runs in rooms where heat dispersion in minimal over time.
ACTIVATION /DE-ACTIVATION OF AUTO-ECO MODE
This mode optimises product consumption if it runs in well insulated rooms.
AUTO-ECO
appears on the control panel display when this option is activated.
Press any button on the first screen with OFF and MENU will appear on the screen. Use the button in the bottom right corner to scroll until
IMPOSTAZIONI (SETTINGS) appears, press the button in the top left corner relative to SET, scroll once again with the bottom right button
until AUTO-ECO appears. Select SET once again in the top right corner and set OFF or ON from the bottom left corner and press OK to save
the setting. When you return to the main menu you will note that the Mode setting is ECO, then press the bottom left or right buttons to set
the respective temperature and speed of the fans for the hot air expulsion. Follow the same procedure to disable the AUTO-ECO function.
Example of AUTO-ECO mode operation
If the room temperature detected by the probe and shown on the control panel is 15°C and the temperature is set to 20°C, the product will
move to the 5th power (according to a preset ramp-up) and once the target temperature is reached (20°C), the stove will modulate and
then automatically switch off temporarily (STANDBY). When room temperature drops below the set value on the control panel (e.g. 18°C),
and sufficient switch-off time has elapsed, the product will automatically restart and run until it reaches 20°C again. If the room probe
temperature reading continues to exceed the thermostat setting (e.g. 20-21°C), the product will stay off.
In this mode, the user can switch the product on by resetting the thermostat to a temperature that is higher than the room temperature,
or by switching the appliance off by pressing button B for a few seconds and then switching it back on by pressing the same button.
There is no need to reset the “
AUTO-ECO
” mode as this is saved from the previous use.