36
9-EMERGENCY PANEL
FEED SCREW LOADING
This function can only be activated when the product is off and allows the pellets to be loaded into the feed screw (loading system). It
can be used each time the pellets finish in the feed screw and hopper (see alarm A02). It is useful to prevent failed start-ups (alarm A01)
due to the hopper being empty.
The FEED SCREW LOADING function is activated as follows (with the product off): bring selector
“D”
on the emergency panel to OFF and
press key
TEST
on the same panel three consecutive times. Wait a few seconds and FEED SCREW will flash on the display.
Press the TEST key once again when the pellets begin to fall into the brazier to end the FEED SCREW LOADING function and proceed with
the product start-up.