9-EMERGENCY PANEL
EMERGENCY PANEL START-UP/SHUTDOWN
NIf the remote control is faulty or the batteries are flat, the product can be operated in safe mode via the rear emergency panel.
In this configuration, the product can only work in manual mode and one of
3
power levels can be selected.
•
APPLIANCE START-UP WITHOUT THE REMOTE CONTROL
Switch the product on by bringing selector
“D”
to the
ON
position. The RED LED goes off upon start-up, whereas the GREEN LED starts
to flash until the start-up phase is complete. Once the product runs smoothly, the GREEN LED remains on.
•
SELECTING THE POWER WITHOUT THE REMOTE CONTROL
One of three heating powers
MIN-MED-MAX
can be selected (selector
“E”
):
The
MINIMUM
power corresponds to the 1
st
power.
The
MEDIUM
power corresponds to the 3
rd
power.
The
MAXIMUM
power corresponds to the 5
th
power.
•
APPLIANCE SHUTDOWN WITHOUT THE REMOTE CONTROL
Switch the product off by bringing selector
“D”
to the
OFF
position.
Once the remote control is restored, remember to set selector “D” back to the “REMOTE” position, otherwise the