8-LCD REMOTE CONTROL
Technical Dept. - All rights reserved - Reproduction is prohibited
VARIOUS SETTINGS
ROOM VENTILATION
The room ventilation can be adjusted as desired in all 4 operating modes described earlier on. Simply follow the steps below: press key
D on the initial display to access the
VENTILATION
setting. Then press key C to set the desired ventilation by selecting one of the 5 levels
available. The “auto” option can also be selected, which automatically links the room ventilation speed to the flame level.
In brief:
flame set to 1 > ventilation set to 1; flame set to 3 > ventilation set to 3; flame set to 5 > ventilation remains set to 3 (for silent operation
as it is in automatic mode).
The speed of each fan (identified with 1 or 2 above the level bars) in products with 2 fans (comfort air models) can be scrolled and set via
key D.
NOTE: If the remote control is replaced with a new one and the default settings must be changed, proceed as follows: press keys
D + E simultaneously for 10 seconds while the remote control is switched on (until the flashing number disappears). Press key
C to select 1 or 2 according to the product to which the remote control is to be paired, and press E to exit.
SLEEP FUNCTION
The sleep function allows a shutdown time to be set quickly. This function is only available in the
MAN
and
AUTO
modes. It is set as
follows: from the
VENTILATION
setting (press key D - see the previous paragraph), press key
D
again to access the
SLEEP
setting.
The shutdown time is set in 10 minute intervals via key
C
. Confirm via key
D
or
E
and the display returns to the initial page on which the
sleep shutdown time remains displayed. Disable the
SLEEP
function by simply accessing the setting and decreasing the time until dashes
are displayed and then confirm.