Installation and Operational Instructions for
ROBA
®
-brake-checker plus AC Type 029.700.2
(B.0297002.EN)
your reliable partner
26/06/2019 HH/GF
Page 7 of 10
Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421
www.mayr.com
, E-Mail:
77
EMC-compatible Installation
The measure described for compliance with the EMC
directive is examined under laboratory conditions, and cannot
necessarily be bindingly transferred onto the condition of a
machine or system in case of deviations.
Scope of the inspection:
• Monitoring module ROBA
®
-brake-checker
• released ROBA
®
-stop safety brake
• Input voltage up to 500 VAC
Measure
Installation of a line filter in the AC-supply line
(e.g. Schaffner FN 2415-10-29)
• Avoid antennae effects:
Keep the supply cables as short as
possible;
do not form rings or loops with the
cables!
• Mount good earth connections onto the
metal body of the brake!
• Lay control cables separately from power
cables or from strongly pulsating supply
cables!
• During operation with a frequency con-
verter, please ensure EMC-compatible
installation of the frequency converter!
• Please always check the holding voltage
during operation of all components in the
system!
• For operation in residential and small
business areas, special precautions must
be taken in order to keep to the correct
limit values for these areas with the com-
plete system.