Installation and Operational Instructions for
ROBA
®
-brake-checker plus AC Type 029.700.2
(B.0297002.EN)
your reliable partner
26/06/2019 HH/GF
Page 4 of 10
Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421
www.mayr.com
, E-Mail:
44
Technical data
Brake nominal voltage
104 VDC
180/207 VDC
Supply voltage,
power terminal acc. DIN 50160
U
I
[VAC]
200 – 480 / 320
1)
Input voltage (control
terminal)
SELV/PELV
Ripple
content ≤5 %
U
I
[VDC]
24
(7 - 30)
Output voltage
Reduction
U
O
[VDC]
104
207
2)
U
H
[VDC]
52
104
Output voltage
overexcitation
U
O
[VDC]
185
360
2)
U
H
[VDC]
104
185
2)
Output current
at ≤45 °C
I
RMS
[A]
2
at ≤60 °C
I
RMS
[A]
1
at ≤70 °C
I
RMS
[A]
1
Terminals
Control terminal
Nominal cross-section 0.34 – 2.5 mm² (22 – 14 AWG)
tightening torque screws: 0.29 Nm/3.5 lb-in
Power terminal
Nominal cross-section 0.2 – 2.5 mm² (22 – 14 AWG)
tightening torque screws: 0.5 Nm/7 lb-in
Device fuses
Control terminal
Fuse 315 mA, slow acting
Power terminal
Max. 2 A circuit breaker, characteristic K/Z
(rated brake current)
Device ambient temperature
[°C]
-25 to +70 / -25 to +60
Storage temperature
[°C]
-40 to +105
Conformity markings
/
Protection
IP20
Installation conditions
The installation position can be user-defined.
Please ensure sufficient heat dissipation and air convection!
Do not install near to sources of intense heat!
1) CSA-C22.2 No. 14-18
2) Approx. 0.9 × U
I
(supply voltage, power terminal)
Preventative function monitoring
Through the monitoring of different parameters, the ROBA
®
-brake-checker recognises safety critical operating conditions of the
brake in advance, as well as acute faults (e.g. line breakage). These are determined as they occur and are notified to the user
as a warning before the brake can no longer be operated.
Only the mechanical switching function is checked. Conclusions on the braking torque are not possible (e.g. reduced friction
value due to oiling of the brake lining)
Possible causes for the warning:
• Increasing wear
• Rising coil temperature
• Falling supply voltage
• Line voltage drop on feed lines to the brake
Size
Type
Input voltage
±10 % acc. EN50160
Output voltage
± 10%
Brake volt-
age
Operation mode
Article number
[VAC]
U
O
[VDC]
U
H
[VDC]
[VDC]
20
029.700.2
200 - 275
104
52
104
power reduction
8269426
230 - 480/320
1)
207
2)
104
207
power reduction
8269424
200 - 480/320
1)
185
104
104
overexcitation
8264926
400 - 480/320
1)
360
2)
185
2)
207
overexcitation
8269425
44