Installation

LOCATION

The tank must sit level or slope slightly
towards the drain valve to allow the
tank to drain properly.
It is extremely important to install the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than
100°F.
A minimum clearance of 4 inches
between the compressor and a wall is
required because objects could obstruct
air flow.

Do not

locate

the compressor air inlet near steam,
paint spray, sandblast areas or any
other source of contamination. This
debris will damage the motor.

ELECTRICAL INSTALLATION 

All

wiring

and electrical connections should be
performed by a qualified electrician.
Installation must be in accordance with
local codes and national electrical
codes.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug
illustrated in Figure 1. Make sure the
product is connected to an outlet
having the same configuration as the
plug. This product must be
grounded. In the event of an
electrical short circuit, grounding
reduces risk of electrical shock by
providing an escape wire for electric
current. This product is equipped
with a cord having a grounding wire
with an appropriate grounding plug.
Cord must be plugged into an outlet
that is properly installed and
grounded in accordance with all
local codes and ordinances.

General Safety
Information 

(Cont.)

OPERATIONAL SAFETY

Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:

1. Read all manuals included

with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the
equipment.

2. Follow all local electrical and safety

codes, as well as in the U.S.A.,
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the compressor.

4. Keep visitors away and NEVER allow

children in the work area.

5. Wear safety glasses and

use hearing protection
when operating the pump
or unit.

6. Do not stand on or use the pump or

unit as a handhold.

7. Before each use, inspect compressed

air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.

8. Check all fasteners at frequent

intervals for proper tightness.

Motors, electrical equipment
and controls can cause
electrical arcs that will ignite
a flammable gas or vapor.
Never operate or repair in or near a
flammable gas or vapor. Never store
flammable liquids or gases in the
vicinity of the compressor.

Compressor parts may be 
hot even if the unit is
stopped.

9. Keep fingers away from a running

compressor; fast moving and hot
parts will cause injury and/or burns.

2

Oilless Compressors

10. If the equipment should start to

abnormally vibrate, STOP the
engine/motor and check
immediately for the cause.
Vibration is generally a warning of
trouble.

11. To reduce fire hazard, keep

engine/motor exterior free of oil,
solvent, or excessive grease.

Never 

remove

or attempt to adjust safety valve. Keep
safety valve free from paint and other
accumulations.

Never attempt to repair or
modify a tank! Welding,
drilling or any other
modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn or
damaged tanks.

Drain 

liquid

from tank daily.

12. Tanks rust from moisture build-up,

which weakens the tank. Make sure
to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and
corrosion.

13. Fast moving air will stir up dust and

debris which may be harmful.
Release air slowly when draining
moisture or depressurizing the
compressor system.

SPRAYING PRECAUTIONS

Do not spray flammable
materials in vicinity of open
flame or near ignition
sources including the
compressor unit.

14. Do not smoke when spraying paint,

insecticides, or other flammable
substances.

15. Use a face mask /

respirator when spraying
and spray in a well
ventilated area to prevent
health and fire hazards.

16. Do not direct paint or other sprayed

material at the compressor. Locate
compressor as far away from the
spraying area as possible to
minimize overspray accumulation
on the compressor.

TEST

RESET

Grounded Outlet

Grounded

Pin

Figure 1

MANUAL

www.maxustools.com

Содержание EX1001

Страница 1: ...he State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling Please read and save these instructions Read carefully before attempting to assemble insta...

Страница 2: ...sitors away and NEVER allow children in the work area 5 Wear safety glasses and use hearing protection when operating the pump or unit 6 Do not stand on or use the pump or unit as a handhold 7 Before...

Страница 3: ...fer from area to area Source wiring plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate and meet all electrical codes for this minimum 2 Use a slow blow...

Страница 4: ...ut off flow of air completely OUTLET PRESSURE GAUGE 1 This gauge shows at a glance air pressure at outlet Air pressure is measured in pounds per square inch psi 2 Be sure this gauge reads ZERO before...

Страница 5: ...lve with air in tank bleed tank 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2 Replace or repair Do n...

Страница 6: ...limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product H Additional items not covered under this warranty 1 All Compressors a...

Страница 7: ...vant de mettre ce produit en service En cas de dommage ou de parties manquantes S V P composer le 1 888 MAXUS4U pour demander conseil ou appeler un Centre De Service Autoris Maxus S il vous pla t lire...

Страница 8: ...t son utilisation 2 Suivre tous les codes de s curit locaux ainsi que les National Electrical Codes NEC and Occupational Safety and Health Act OSHA des U 3 Seules les personnes bien familiaris es avec...

Страница 9: ...a pression du r servoir arrive la pression maximale r gl e d avance Dans la position OFF le compresseur ne fonctionnera pas Cet interrupteur devrait tre dans la position OFF pendant le branchement ou...

Страница 10: ...nne obstru par la surpulv risation PROTECTEUR DE SURCHARGE THERMIQUE Ce compresseur est dot d un protecteur de surcharge thermique r armement manuel qui coupera le moteur s il surchauffe Si le protect...

Страница 11: ...idanger le r servoir 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres appareils lectriques du circuit ou faire fonctionner le compresseur sur un circuit unique 2 Rem...

Страница 12: ...ricant de moteur qui est fournie avec le produit H Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dit...

Страница 13: ...edidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe...

Страница 14: ...el equipo 2 Siga todos los c digos de seguridad laboral y electricidad establecidos en su pa s por ejemplo los de la NEC y OSHA en EUA 3 Este compresor s lo debe ser usado por personas que est n bien...

Страница 15: ...erna del aislante es verde con o sin rayas amarillas es el cable de conexi n a tierra Nunca conecte los cables verdes o verde con rayas amarillas a un terminal con tensi n 3 Cons ltele a un electricis...

Страница 16: ...Esta perilla controla el aire comprimido que se le suministra a las herramientas neum ticas o pistolas pulverizadoras 2 Gire la perilla en el mismo sentido de las agujas del reloj para aumentar la pr...

Страница 17: ...be colocarse lo m s lejos posible del rea de trabajo seg n lo permita la longitud de la manguera para evitar que el filtro se atasque PROTECTOR TERMICO Este compresor est equipado con un protector de...

Страница 18: ...e 1 Cerci rese de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 2 Reempl cela o r...

Страница 19: ...clu dos de la cobertura de esta garant a limitada stos deben ser enviados por el comprador al fabricante original o a los centros de servicio autorizados por el fabricante para que se les den servicio...

Страница 20: ...EX1001 EX2001 EX8017 20 Oilless Compressors Compresseur Sans Huile Compresores Sin Aceite Notes Notas...

Отзывы: