Maxtronic Orion 410ST User Guide
51
Stor
age
Se
tu
p Settings
Storage Setup Settings
The Storage Setup menu allows the administra-
tor to configure various settings according to the
disks and volumes installed.
The following information is displayed:
Disk Information:
•
Name
: Displays the name of the HDD.
•
Model
: Displays HDD model.
•
Capacity
: Displays the HDD capacity.
•
Status
: Displays storage volume location.
For more information related to an installed
HDD, double-click ‘Disk name’. The following
screen will appear:
• CRC (Cyclic Redundancy Check) error indi-
cates that an error has occurred during the
data transmission between hard disk and
IDE controller. When a CRC error occurs,
the read/write command is attempted again.
The greater the number of errors, the more
unstable the hardware.
• ECC (Error Correction Code) error indicates
a defect in the hard disk.
• Maximum speed: Displays the maximum speed of the disk.
• The bad sector count feature allows a maximum of 512 blocks. When the count reaches
384, the system will automatically notify the user. Once the count has reached the maxi-
mum of 512, the system will disable the hard disk.
Both the CRC and ECC counters will be reset to zero following system
reboot.
Once the bad sector count has reached 384, we strongly recommend
replacing the hard disk immediately to prevent any data loss.