41
8.11 02b5 error TroUbleSHooTiNG
CHaPTer 8: TroUbleSHooTiNG
error meSSaGe 02b5
1) causE:
a. The inverter sensor is reading the normal rated current is over 10.5 amps for 60 seconds.
2) sOLuTION:
a.Useamulti-metertocheckthe3points(U/V/W)andseeifinsideresistanceisover4Ω(FiguresA.B&C).
-- If yes, replace the motor.
-- If no, flip the deck and / or replace the running belt.
b. Replace the MCB if all other solutions fail.
fiGUre a
fiGUre b
fiGUre C