55
fiGUre e
fiGUre f
9.9 moTor rePlaCemeNT - CoNTiNUed
7) Disconnect the motor cable from the MCB (Figure E).
8) Remove the 4 screws holding the motor to the frame (Figure F).
9) Remove the motor from the treadmill.
10) Reverse Steps 1-9 to install a new motor.
NOTE:
Be sure that the motor isolator pad is in place prior to mounting the new motor (Figure G).
11) Test the treadmill for function as outlined in Section 9.21.
fiGUre G