![Master Pumps MPC750COMPACT Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/master-pumps/mpc750compact/mpc750compact_original-instructions-manual_1737634013.webp)
13
Venting the pump before use
▪
Always ensure that the pump is vented properly
before commissioning the pump. Possibly tilting
back and forth several times until no more air
bubbles appear, wait at least 15 seconds before the
pump to start.
This appliance cannot be used by children or
people who are physically, mentally or
developmentally impaired, or people who lack
experience or knowledge, except in case
these people receive instruction from a person
responsible for their safety, a supervisor, or by
studying the preceding instructions concerning
use of this appliance.
Build-in floating switch
▪
When the switch is on the top “manual”, pump
will be running continuously without
stopping. User has to move the switch down or plug
off to stop the machine.
▪
When the switch is at ‘Automatic’ position, the
pump will start when water level is above
12 cm.
CLEANING AND MAINTENANCE
Attention !
Before performing any work
on the equipment, pull the
power plug.
Never use solvents such as
petrol, alcohol, ammonia
water, etc. These solvents
may damage the plastic
parts.
Service
The pump is maintenance free. Defects must
only be repaired by an authorised service
station.
Cleaning
When the pump is often transported in the course
of operation, it should be cleaned out with clear
water after every use.
In case of stationary installation, the function of
the bating switch should be checked every 3
months.
All fibrous particles which may have built-up
inside the pump housing should be removed with a
water jet.
Every 3 months the shaft ground and as should
be cleaned from mud.
Remove deposits on the floater with clear water.
Remove the mains plug
before all maintenance work.
TECHNICAL DATA
Type
Water: clean and slightly dirty
Mains voltage
230 V
Mains frequency
50 Hz
Power input
750 W
No load speed
2800 min
-1
Max. pump capacity l/min
175 l/min
Max. lift
8.5 m
Max. submerging depth
7 m
Max. grain size
3 mm
Max. water temperature
35 °C
Type of protection / Insulation class IPX8
Cable
10m
Gewicht kg
4,9
ATTENTION !
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
must be worn.
Weighted root mean square acceleration according
to relevant standard. : < 2.5 m/s²
The declared vibration total value has
been measured in accordance with a standard
test method and may be used for comparing one
tool with another that the declared vibration total
value may also be used in a preliminary
assessment of exposure.
A warning that the vibration emission
during actual use of the power tool can differ
from the declared total value depending on the
ways in which the tool is used and of the need to
identify safety measures to protect the operator
that are based on an estimation of exposure in
the actual conditions of use (taking account of
all parts of the operating cycle such as the times
when the tool is switched off and when it is
running idle in addition to the trigger time).
Содержание MPC750COMPACT
Страница 2: ...2 4 6 3 1 5 2 7...
Страница 27: ...27 MPC750COMPACT...