55
Attachment 5: CV 55, 57, 114, 116 - Special functions A1, A2, A3, A4
Value
Application
Note
+ 192
Asymmetric flashing (2/3 on, 1/3 off)
short „off“, long „on“
additional value must be added
Attachment 5a: CV 57, 114, 116 - Special functions A2, A3, A4
Value
Application
Note
16
Inverse Coupling with A1, A3 or A5 (Alternating Flashing)
CV57 (A2 with A1)
CV116 (A4 with A3)
30
Pulse simulation for pulsed smoke generator (A3 only)
CV 114
Attachment 6: CV 124 - Servo function A7
Value
Application
Note
0
0 = Servo deactivated
regular switching output
1
1 = Servo activated
+ 4
Control level inverted
+ 8
Switch-off after movement
Attachment 7: CV 149 - MASSOTH Sound Configuration
Bit Value
OFF (Value 0)
ON
Note
0
1
Random generator OFF
Random generator ACTIVE
1
2
Standing phase noise OFF Standing phase noise ACTIVE
2
4
Standard driving Sound
Load-dependent sound
3
8
Cylinder valves closed
Cylinder valves open
only steam locos during
start of movement
4
16
Contacts standard
Reed contact inputs
direction sensitive
5
32
Automatic side noises
OFF
Automatic side noises
ACTIVE
6
64
Start signal delay OFF
Start signal delay ON
since V1.2 (written in
CV 7)