53
Attachment 3: CV 51, 52, 54, 56, 113, 115
Switch output commands Light front / rear, A1, A2, A3, A4
Value
Application
Note
0... 16
0 = Switch function with light key,
1 ... 16 = Switch function with F-key No. 1-16
31
Switching output always on
only A2, A4
(0... 16)
+ 64
Switching output "on" in reverse Only
additional value must be added
(0... 16) +
128
Switching output „on“ in forward Only
additional value must be added
Anhang 4: CV 53, 112 - Dimmfunktion A1, A2, A3, A4
Value
Application
Note
1... 32
Voltage in Percent of Track Voltage on Output
(Both outputs dimmed)
1 Unit = approx. 3% of track voltage
1 = 3% of track voltage (0.75V)
32 = 100% track voltage (24V)
(1... 32)
+ 64
A1 resp. A3 is dimmed only
S1 = value in CV53
S3 = value in CV112*
(1... 32)
+ 128
A2 resp. A4 is dimmed only
S2 = value in CV53
S4 = value in CV112*
Attachment 5: CV 55, 57, 114, 116 - Special functions A1, A2, A3, A4
Value
Application
Note
0
0 = Steady „on“
(Standard operation)
1 - 15
Flashing symmetrical
(Time base 0,25 sec/value)
symmetric flashing
+ 64
Short term function (Monoflop)
(Time base 0,25 sec/value)
output switches off after time
out
additional value must be added
+ 128
Asymmetric flashing (1/3 on, 2/3 off)
short „on“, long „off“
additional value must be added