47
Table of configuration variables
CV Description
A Range Note
175 1. Standing noise : Number of loops
*
0...15
0= no sound repetition:
the sound will be triggered only
once / 1…15: number of repeti
-
tions: e.g. the number of air pump
sounds
176 2. Standing noise : Number of loops
*
0...15
177
3. Standing noise : Number of loops
*
0...15
178
4. Standing noise : Number of loops
*
0...15
179
Time value of random generator
3
1...3 1=frequent / 3=infreq. triggering
180
1. Random sound: Sound allocation
*
0...12 0= no random sound
1…12= assignment of additional
sounds: the sounds selected are
triggered randomly
181 2. Random sound: Sound allocation
*
0...12
182 3. Random sound: Sound allocation
*
0...12
183
4. Random sound: Sound allocation
*
0...12
184
1. Random sound: Number of loops
*
0...15
0= no sound repetition: the sound
will be triggered only once
1…15= number of repetitions:
e.g. number of air pump sounds
185 2. Random sound: Number of loops
*
0...15
186 3. Random sound: Number of loops
*
0...15
187
4. Random sound: Number of loops
*
0...15
188
moving forward signal sound allocation
*
0...12 0= no sound allocated
1…12= allocation of additional
sounds (The sound selected will
be presented depending on the
operational status of the locomo-
tive)
189
moving backwards signal sound alloc.
*
0...12
190
(Reed) contact 1: Sound allocation
*
0...12
191 (Reed) contact 2: Sound allocation
*
0...12
192
Brake application: Sound allocation
*
0...12
193
Trigger threshold sound output analog
*
0...255
alignment of the sound to the mo-
tor RPM when starting to move
194
Trigger threshold sound output digital
*
0...255
195
Pulse generator control register
0
0...4
0= no external pulse generator
1…4= number of magnet poles
per each steam chuff
196
Duration of a steam chuff
28 0...32 0…32= duration of a steam chuff
198
Spacing between steam chuff
1
0...16
0…16 pause time between chuffs
(only active if CV195 is set to „0“)
200
Total volume level
32
1...63
or 255
1= low, 63= loud,
255= ext. potentiometer