49
Table of configuration variables
CV Description
A Range Note
201
Add. sound 1: Individual volume level
*
0...3 0= 25% volume level
1= 50% volume level
2= 75% volume level
3= 100% maximum volume
202 Add. sound 2: Individual volume level
*
0...3
203 Add. sound 3: Individual volume level
*
0...3
204
Add. sound 4: Individual volume level
*
0...3
205
Add. sound 5: Individual volume level
*
0...3
206 Add. sound 6: Individual volume level
*
0...3
207
Add. sound 7: Individual volume level
*
0...3
208 Add. sound 8: Individual volume level
*
0...3
209 Add. sound 9: Individual volume level
*
0...3
210
Add. sound 10: Individual volume level
*
0...3
211
Add. sound 11: Individual volume level
*
0...3
212 Add. sound 12: Individual volume level
*
0...3
217
Volume turn-on phase
*
0...3
218
Volume standing phase
*
0...3
219
Volume turn-off phase
*
0...3
220
Volume driving phase
*
0...3
221
Volume turn-on phase
*
0...3
two force locomotives only
222
Volume standing phase
*
0...3
223
Volume turn-off phase
*
0...3
224
Volume driving phase
*
0...3
229
Trigger threshold 1 contact switch dig.
16 0...255
230 Trigger threshold 2 contact switch dig.
32 0...255
231 Trigger threshold 3 contact switch dig.
48 0...255
232
Trigger threshold 4 contact switch dig.
112 0...255
233
Trigger threshold 5 contact switch dig.
160 0 ... 255
234
Sound on accelerate, contact switch
11
0 ... 255
235
Switching timer
4
0...16 (0,15 sec/value) 0 = deactivated
236
Power Buffer timer
->
0 ... 255 Diesel = 55 / Steam = 250
255
Decoder type
read only