(only if BATCH TOTAL < (WP/EP) values. No new batch will be started by
STOP
key.
When batch total value crosses the WP/EP value, relays gets OFF and batch is
over.
Again if START key is pressed then a new batch will start making BATCH TOTAL
= 0. Batching relays gets ON.
8.4 Edit Mode
In this mode user can verify or modify, various parameters.
To enter the EDIT mode, correct password is to be entered.
Password Protection
When INDEX key is pressed, following prompt will be displayed at lower panel 7-segment
display.
“bt tot” , then
“Int tot” , then
“roL Cnt “ , then
“PASS” .
User Can select the Parameter
–any of the above prompt to display corresponding value by
pressing INDEX key and then pressing
“START KEY”(It is digit select key for editing the
parameters),
At the selection of password,
value “0000” is displayed.
Enter the correct password value with the help of START (digit select key) and STOP key
(Incr key) and press INDEX KEY (INDEX key is used as ENTER key)
If correct password is entered & INDEX key is pressed, it will show the first mode PROG
MOD. If wrong password is entered, then “0000” MSG will be displayed.
Parameter Description
There are total three Menu Items:
Three parameters are displayed after entering correct password.
These parameters related with totaliser are mentioned in the following table.
1.
Program Mode
2.
Configuration Mode
3.
Calibration Mode