Stand-Alone programming overview
27
there are two rules of thumb that will make life much easier; try to ensure
that:
1 Every fixture has the same number of scenes.
2 Respective scene times are a few seconds longer on the fixture that issues
triggering commands.
The rules used in the algorithm are detailed in “Synchronous triggering
during Stand-Alone operation” on page 35.
Synchronizing scene changes for
multiple Imagers
In situations where you are running multiple Imagers on a data link it is
possible to synchronize scene changes. Read this section if this applies in
your case.
It is important to note that each individual fixture must be programmed with
a show and that the only commands that are passed are scene change
commands. No data about the look of the scene is passed between fixtures.
Setting synchronized triggering options
1 Scroll to
S A
in the top level of the menus on the control panel and press
[enter].
2 Scroll to
S A E
and press [enter].
3 Select:
4 Press [enter].
Programming methods
The Imager provides two stand-alone programming methods; using the:
Sin
If the fixture will operate in isolation (with no
synchronous triggering). This is the factory default
setting.
Snd
If the fixture will send scene triggering signals to the
other Imagers on the data link.
Syn
If the fixture should “listen” for scene trigger signals on
the data link.
Содержание Imager Series
Страница 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Страница 5: ...5 SECTION 1 GETTING STARTED ...
Страница 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Страница 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Страница 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Страница 54: ...54 Moving mirror ...
Страница 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Страница 61: ...Printed circuit board layout 61 Printed circuit board layout The PCB can be found behind the control panel ...
Страница 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Страница 81: ...Specifications Imager 81 ...
Страница 82: ......
Страница 83: ......
Страница 84: ...www martin architectural com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...