64
Troubleshooting
L S E
Light sensor error
The light sensor is not working.
Contact your Martin dealer for
service.
L F E
Lamp fan error
The lamp fan speed is too low or
too high. Contact your Martin
dealer for service.
g F E
Gobo fan error
The gobo fan speed is too low or
too high. Contact your Martin
dealer for service.
L h u
Lamp hour warning
Replace the lamp if necessary
L t u
Temperature
warning (lamp
sensor).
Temperature around
the lamp is too high.
Check that there is enough
space around the air vent.
Check that the ambient
temperature does not exceed
40° C (104° F).
Contact your Martin dealer for
service.
g t u
Temperature
warning (gobo
sensor) Temperature
around the gobo is
too high.
Check that there is enough
space around the air vent.
Check that the ambient
temperature does not exceed
40° C (104° F).
Contact your Martin dealer for
service.
H o t
Hot lamp warning
The lamp is too hot to be turned
on. Wait for the lamp to cool
before attempting to re-strike it.
Message in display
Error
Remedy
Содержание Imager Series
Страница 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Страница 5: ...5 SECTION 1 GETTING STARTED ...
Страница 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Страница 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Страница 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Страница 54: ...54 Moving mirror ...
Страница 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Страница 61: ...Printed circuit board layout 61 Printed circuit board layout The PCB can be found behind the control panel ...
Страница 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Страница 81: ...Specifications Imager 81 ...
Страница 82: ......
Страница 83: ......
Страница 84: ...www martin architectural com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...