Revision 1.4.18
Page 61
6.5
Maretron DCM100 Configuration
This describes the configuration of the Maretron DCM100 firmware version 1.0.4.
Figure 47
– DCM100 Configuration Screen
6.5.1 Advanced Configuration
Advanced Configuration changes some complex parameters within the device, and should only be
performed by an advanced user. Typically advanced configuration is only done at installation and
should not need to be done while at sea.
Figure 48
– DCM100 Advanced Configuration Screen
6.5.1.1 Current Sensor Type
Three different current sensors may be attached to the DCM100. Options are:
200A
– A 200 Amp Current Transducer is connected to the DCM100. This has the part number
LEMHTA200-S.
400A
– A 400 Amp Current Transducer is connected to the DCM100. This has the part number
LEMHTA400-S.
Содержание DSM150
Страница 16: ......
Страница 163: ...Revision 1 4 18 Page 147 Figure 153 RAA100 Setting the to Sender Gauge Resistance...
Страница 233: ...Revision 1 4 18 Page 217 Figure 254 Favorite Screen Showing Highlighted Switch Breaker...
Страница 263: ...Revision 1 4 18 Page 247 Figure 288 Restore Factory Defaults Confirmation...