DSM150
User’s Manual
Page 232
Revision 1.4.18
8.3.7.8.1 Trigger Configuration
Figure 268
– Trigger Configuration – Inside Radius Alert
Re-trigger Period
– When you accept an alert, it will change to the “Accepted” state, and
annunciators that are sounding for that alert will stop sounding. If the condition which caused
the alert remains true after the amount of time in this field, the alert will return to the “Active”
state, and annunciators will begin sounding again for that alert. If a value of 0:00 is entered,
then the alert will never re-trigger.
Alert Set Point
– If the distance between the current GPS position and the reference position falls
below above the value in this field, the alert will become active.
Alert Set Delay
– The distance between the current GPS position and the reference position must
fall below the Inside Radius Alert Set value for longer than the time in this field in order for an
alert to become active.
Alert Clear Point
– If the alert is active and the distance between the current GPS position and
the reference position rises above the value in this field, the alert will become inactive.
Alert Clear Delay
– The distance between the current GPS position and the reference position
must rise above the Inside Radius Alert Clear value for longer than the time in this field in order
for an alert to become inactive.
Latitude
– The latitude of the reference position. This may be typed in as <degrees>:<minutes>
followed by an N or S. If the N or S is missing, North is assumed. Moving the cursor to another
field will reformat the contents of this field.
Longitude
– The longitude of the reference position. This may be typed in as
<degrees>:<minutes> followed by an E or W. If the E or W is missing, East is assumed.
Moving the cursor to another field will reformat the contents of this field.
Get Current Position
– Selecting this line will transfer the current GPS position into the Latitude
and Longitude fields.
8.3.7.9 Trigger Type is Anchor Alert
The Anchor Alert is a special case of the Outside Radius Alert (section 8.3.7.7). It is used to signal an
alert whenever the vessel moves outside a programmable distance in any direction away from a
reference point (expressed as a longitude and latitude). This alert is useful when the vessel is
anchored or moored and the vessel should not drift outside a perimeter and if it does, an alert is