Each time you press
Accept
during this process and after the Current Point highlight advances, put
more fluid into the tank, and note the total volume of fluid pumped into the tank at this point. Use the
Increase
and
Decrease
keys to set the current tank level to the appropriate value, and then press the
Accept
key to store the current calibration point and advance to the next calibration point. Figure 104
shows a screenshot of these intermediate calibration points.
Figure 104
– Intermediate Level Calibration
Once the tank is completely full, instead of pressing the
Accept
key to store the current calibration
point, press the
Complete
key. This will complete the calibration process and will also adjust the tank
capacity to the currently indicated level. Figure 105 below shows the calibration screen at the last
point with the full tank level (and thus the tank capacity) set to 101 gallons.
Figure 105
– Full Level Calibration
After you press accept, a confirmation screen will appear showing completion of the calibration
process and the new tank capacity value. A screenshot of this calibration screen is shown below in
Figure 106.