Revision 1.4.18
Page 159
enabled sentences. In the figure, you can see that the HDG and ROT sentences will be transmitted
every 0.1 second (10 times/second), the ATT sentence will be transmitted once per second, and the
HDM and HDT sentences are disabled.
The last line in the menu enables you to program the lifetime of the variation data received by the
SSC200. In Figure 169, you can se
e that the “Variation Time” has been programmed to 5.0 seconds.
This means that if the compass has not received magnetic variation for five seconds, it will no longer
transmit true heading data, as the variation data it has received is now expired. On the NMEA2000
side, the Heading PGN has separate fields for heading sensor reading and variation. The SSC200
always has magnetic heading available; when variation is not available (timeout or invalid) the
variation field is set to N/A. The default value of 5.0 seconds should be adequate for the majority of
applications, but it may need to be increased for variation sources that transmit less frequently.
Figure 169
– SSC200 NMEA 0183 Sentence/Rate Selection Screen
6.23.2.3.3 Load Default Sentence / Rate Selection
The Load Default Sentence / Rate Selection option will reset the NMEA 0183 sentence
enable/disable status, along with transmission intervals and variation time, to their factory default
settings.
Figure 170
– SSC200 Load Default Periodic Rate Selection
Содержание DSM150
Страница 16: ......
Страница 163: ...Revision 1 4 18 Page 147 Figure 153 RAA100 Setting the to Sender Gauge Resistance...
Страница 233: ...Revision 1 4 18 Page 217 Figure 254 Favorite Screen Showing Highlighted Switch Breaker...
Страница 263: ...Revision 1 4 18 Page 247 Figure 288 Restore Factory Defaults Confirmation...