3.10 Electrical wiring for Eletta
®
Covering System
The application of the motorized covering system requires the installation of an elementary wiring, suitable for supplying
electricity and the proper functioning of the covering.
The system equipment includes, apart from the above-described motor, following material:
•
Motor Control Unit (X)
see paragraph 3.10.1
•
Radio remote control
•
Set of electrical contacts
•
Electrical wiring
The electrical system also includes the connection cables for the various components.
Each supplied cable has been prepared and adapted for a specific application. Therefore, each one is marked with a special
initial.
The table below shows characteristics, application and identification marking of the several connection cables.
Length
Cable End 1
Reference Colour
Cable End 2
Application
4.50 m
Open ended for
cutting to length to
connect to battery
A
80 A female plug
Connection from the tractor
battery to the tipper trailer
connection zone
2.50 m
80 A male plug
B
Open ended for
cutting to length to
connect to Motor
Control Unit
(
Red
–
Black
)
Connection from the tipper trailer
connection zone to the Motor
Control Unit power supply
2.50 m
Connection to
Motor Control Unit
terminals
(Yellow
–
Yellow)
C
Open ended for
cutting to length to
connect to contact
plate
Connection from Motor Control
Unit (motor output) to contact
plate
4.50 m
Connection to
contact plate
terminals
D
Open ended for
cutting to length,
for connection to
the motor
Connection from contact plate to
motor
WARNING!
Prior to establish the electrical connections, “disconnect the ba
t
tery”.
The wiring system must be made by qualified personnel in strict accordance with the instructions
described in this manual and the wiring diagram shown in paragraph 6.1.
Note:
If the use of different cables than those supplied should be necessary, consult previously the manufacturer.
3.10.1 Motor Control Unit models description
The following table summarizes the various types of the Motor Control Unit (X), with (X) = 1, or 2, or 3, depending on model.
FAMILY PRODUCT
DESCRIPTION
DIFFERENCES FROM STANDARD
MOTOR CONTROL UNIT 1
STANDARD model, in this version the mode
of functioning provides two pushbuttons for
withdrawing
(“uncovered”
switc
h)
and
deploying (“covered” switch) the tarpaulin.
An emergency stop pushbutton with safety
lock is also installed.
A timing circuit for tarp moving backwards
is also installed, provided for tail lift tipper
bodies.