–42–
MANUAL START OPERATION
Step 1.
Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 2.
To start the automatic cleaning system, move
the toggle switch to the CLEAN position. The water will
flow through the water dump valve and down the
drain. The Clean light* will turn on to indicate the ice
machine is in the cleaning mode. The AuCS
®
then
automatically adds cleaner or sanitizer to the ice
machine.
Step 3.
The ice machine will automatically time out a
ten-minute cleaning or sanitizing cycle, followed by six
Rinse cycles, de-energize the Clean light* and stop.
This entire cycle lasts approximately 25 minutes.
Step 4.
After the cleaning or sanitizing cycle stops,
move the toggle switch to ICE position.
Step 5.**
A. The ice machine may be set to start and finish a
cleaning or sanitizing cycle, then automatically start
ice making again.
B. You must wait about one minute into the cleaning
cycle (until water starts to flow over the evaporator),
then move the toggle switch from CLEAN to ICE
position.
C. When the cleaning or sanitizing cycle is completed,
the Clean light will turn off and an ice-making
sequence will start automatically.
*
*The Q1400C ice machine control board does not energize
a Clean light.
**The Q1400C ice machine control board can not perform
step 7, and must remain in the CLEAN position until the
Clean cycle is finished. Moving the toggle switch to the ICE
position will initiate the Rinse cycles. The six Rinse cycles
must be completed before a Freeze cycle can be initiated.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.