–39–
SANITIZING PROCEDURE
Use sanitizer to remove algae or slime. Do not use it to
remove lime scale or other mineral deposits. To initiate
a sanitizing cycle using Manitowoc’s Patented
Cleaning/Sanitizing Technology, use the following
procedure.
Step 1.
Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 2.
To start a sanitizing cycle, move the toggle
switch to the CLEAN position. The water will flow
through the water dump valve and down the drain. The
Clean light* will turn on to indicate the ice machine is
in the cleaning mode.
Step 3.
Wait about one minute or until water starts to
flow over the evaporator.
Step 4.
Add the proper amount of Manitowoc Ice
Machine Sanitizer to the water trough.
*The Q1400C ice machine control board does not energize a
Clean light.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.
QuietQube
®
Models
Amount of Sanitizer
Q0600C/Q0800C/Q1000C/
SU1000C/Q1400C
3 ounces (90 ml)
QDUAL
6 ounces (180 ml)
Содержание CVD0675
Страница 2: ......
Страница 75: ... 69 QDUAL DISTRIBUTION TUBE SV1780 EVAPORATOR WATER PUMP WATER CURTAIN WATER TROUGH ...
Страница 153: ... 149 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 203: ......