WATER LEVEL PROBE
Q0600C/Q0800C/Q1000C/QDUAL
1. Loosen the screw that holds the water level probe
in place. The probe can easily be cleaned at this
point without proceeding to step 2.
2. If complete removal is required, disconnect the wire
lead from the control board (1F) inside the electrical
control box.
!
Warning
Disconnect the electrical power to the ice machine at
the electrical disconnect before proceeding.
SV1621
WATER LEVEL PROBE REMOVAL
Q0600C/Q0800C/Q1000C Shown
SCREW
WATER
LEVEL
PROBE
WATER
TROUGH
ICE
MACHINE
SIDE
PANEL
WIRE
LEAD