–177–
Q0600C/CVD675 SERIES REMOTE AIR COOLED
NOTE:
These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20 to 70/
-29 to 21.1
7.8-9.3
8.8-10.4
9.5-11.2
.75-2.5
80/26.7
8.0-9.4
8.9-10.5
9.7-11.4
90/32.2
8.6-10.2
9.8-11.5
10.6-12.5
100/37.8
9.7-11.4
11.0-12.9
12.0-14.0
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20 to 70/
-29 to 21.1
635
575
540
80/26.7
625
570
530
90/32.2
585
525
490
100/37.8
530
475
440
1
Based on average ice slab weight of 4.12-4.75 lb.
2
Regular cube derate is 7%.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10.0
260-215
46-26
140-185
70-95
70/21.1
270-220
51-26
150-190
70-100
80/26.7
285-225
56-27
155-195
80-105
90/32.2
295-235
59-28
165-200
85-105
100/37.8
340-260
60-30
180-210
85-112
110/43.3
385-300
65-34
195-230
90-120