–196–
Suction Line Filter
The suction filter traps particulate only and does not
contain a desiccant. The filter needs replacement
when:
1. The pressure drop across the drier exceeds 2 psig.
2. The total system refrigerant charge has escaped
and the refrigeration system has been exposed to
the atmosphere.
3. A compressor is replaced.
4. Refrigeration system contains contaminants.
Listed below is the recommended OEM field
replacement filter:
Suction Line Filter
Model
Drier
Size
End
Connection
Size
Part
Number
CVD0675
CVD0875
ASF35S5
5/8 in.
82-5030-3
CVD1075
CVD1475
CVD1476
ASF45S6
3/4 in.
82-5026-3
CVD1875
CVD2075
ASF45S7
7/8 in.
82-5027-3