6
LDVR Series Direct Vent Gas Fireplace
10007317
A) Flat on wall
B) Cross corner
C) **Island
D) *Room divider E) *Flat on wall corner F) Chase installation
Y) 6” minimum
NOTE:
(Fig. )
** Island (C) and Room Divider (D) installation is possible as long
as the horizontal portion of the vent system (X) does not exceed
0’ (610cm). See details in Venting Section.
* When you install your fireplace in(D) Room divider or (E) Flat
on wall corner positions (Y), a minimum of 6” (153mm) clearance
must be maintained from the perpendicular wall and the front side
edge of the fireplace. Refer to (Y) in Figure .
Locating Your Fireplace
Y
E
A
B
C
D
F
Y
B
X
LU584-R
Locating unit
2/23/01 sta
X
Fig. 2
Locate gas fireplace.
LU584-R
Top of Unit to Ceiling ............................... 36” (914 mm)
Appliance
Top .......................................................... 0” (0 mm)
Bottom ..................................................... 0” (0 mm)
Side ......................................................... 0” (0 mm)
Back ........................................................ 0” (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides .............................. 1” (5 mm)
Rear Vent Applications:
Top ........................................................ ” (50 mm)
Sides and Bottom .................................. 1” (5 mm)
Flex Vent ............................................ 7/8” ( mm)
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This also
applies to the distance between the mantel leg (if fitted)
and the fireplace.
For the correct mounting height and widths refer to Figs.
3a and 3b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram
and chart.
Noncombustible mantels and legs may be installed at any
height and width around the appliance.
When using paint or lacquer to finish the mantel, such paint or
lacquer must be heat resistant to prevent discoloration.
Clearance to Combustibles
CFM146
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Top Louvre
Assembly
Top of Combustion
Chamber
Mantel Chart
Mantel Shelf
Mantel from Top
Ref. or Breast Plate Ref.
of Combustion Chamber
Depth
36/39/43 LDVR
33LDVR
V 10” (54 mm) A 17” (43 mm) 16
¹⁄₂
” (419 mm)
W
8” (03 mm) B 15” (381 mm) 14
¹⁄₂
” (368 mm)
X
6” (15 mm) C 13” (330 mm) 1
¹⁄₂
” (318 mm)
Y
4” (10 mm) D 11” (79 mm) 10
¹⁄₂
” (67 mm)
Z
” (51 mm)
E
9” (9 mm) 8
¹⁄₂
” (16 mm)
Fig. 3a
Combustible mantel minimum installation.
3/4” (19 mm) Scribe
Moulding for use with
Vermont Castings
Group Cabinets
CFM170
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
Black
Surround
Face
CFM170
DV Builder Front
View
O
N
M
L
K
Side of
Combustion Chamber
CFM164a
Mantel
Mantel Leg FromSide
Ref.
Leg Depth
Ref.
of Comb. Opening
F
10” (54 mm)
K
11
¹⁄₂
” (9 mm)
G
8” (03 mm)
L
9
¹⁄₂
” (41 mm)
H
6” (15 mm)
M
7
¹⁄₂
” (191 mm)
I
4” (10 mm)
N
5
¹⁄₂
” (140 mm)
J
” (51 mm)
O
3
¹⁄₂
” (89 mm)
Fig. 3b
Combustible mantel leg minimum installation.
3/4” (19 mm) Scribe
Moulding for use with
Vermont Castings Group
Cabinets