15
LDVR Series Direct Vent Gas Fireplace
10007317
DVR584-600
Rear vent no elbows
2/99 djt
20"
(508mm)
Top View
Straight Venting
FP836
Rear Vent-Top View
11/21/98
20"
(508mm)
Max.
REAR VENT-TOP VIEW
20"
(508mm)
Max.
Top View
Rear Vent Corner Installation
Fig. 16
Rear vent applications, one 45° elbow.
45°
45°
Rear Wall Installation
Twist Lock Pipe
STEP 1
Locate vent opening on the wall. To locate hole center
consult with appropriate fireplace dimensions, Page 4.
Frame as shown below.
NOTE:
When using flex vent, the opening will have to be
measured according to the 1/” (13 mm) rise in 1” (305
mm) vertical run.
Combustible Walls
(Fig. 17)
:
Cut a 10
³⁄₈
”H x 9
³⁄₈
” W (64
x 40 mm) hole through the exterior wall and frame as
shown.
Noncombustible Walls
(Fig. 17)
:
Hole opening must be
7
¹⁄₂
” (190 mm) in diameter.
STEP 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 1”/305 mm). Assemble
sleeve and attach to firestop with #8 sheet metal screws
(supplied). (Fig. 18)
VO584-100
Vent Opening
2/99 djt
Vent Opening for Combustible Wall
9
³⁄₈
”
(40mm)
10
³⁄₈
”
(64mm)
Fireplace Hearth
Framing
Detail
Opening for Noncombustible Wall
7
¹⁄₂
”
(190mm)
VO584-100
Fig. 17
Locate vent opening on wall.
ZCS101
Zero Clearance Sleeve
3/11/99 djt
Max. Length
1” (305mm)
#8 Screws ()
#8 Screws
()
Adjustable
Zero Clearance
Sleeve
#8
Screws
()
Adjustable Zero Clearance Sleeve
ZCS101
Fig. 18
Adjustable zero clearance sleeve.
Firestop
STEP 3
Measure from the fireplace collar or elbow face to face
of outside wall (add ” for vent pipe overlap). Mark pipes
and cut to length. It is very important that the two pipes
are flush with the outside wall once the fireplace is in its
final location. (Fig. 19)
STEP 4
Slip 4” and 7” pipes onto respective flue collars. Make sure
to fix to the fireplace collar the 4” pipe with three (3) screws
before fixing the 7” pipe on the 7” collar. Both pipes must
be on a level plane. (Fig 0)
STEP 5
Guide the vent termination 4” collar into the 4” pipe then
the 7” collar into the 7” pipe. Do not force the venting into
position. If the pipes do not line up with the termination
collars, disassemble pipes and reattach to the fireplace
collar. (Fig. 1)
STEP 6
Secure fireplace to floor through floor holes and adjust-
able frame drywall strip (nailing flange) to frame. (Refer to