38
LDVR Series Direct Vent Gas Fireplace
10007317
5. Turn on gas supply and check that plugs are tight and
leak free.
6. Install the enclosed identification label to the valve body
where it can easily be seen.
Conversion is complete.
1. Reassemble the fireplace in the reverse order, except
for the window frame assembly. Leave this off until after
the unit has been checked for leaks and the gas supply
has been bled.
. After bleeding the gas line and checking for leaks with a
soap solution, replace the window frame assembly. Fire
up the unit, check for flame impingement on the logs,
adjusting them if necessary. Check the manifold and
supply pressures against the appliance specifications.
Inlet
PILOT
Pilot Adj.
Outlet
MAIN
FP1769
AF4000 valve face
2/07
"
#/
!0VALVECONVERSION
.
!4
.
!4
,0
,0
Main Connection
Rubber Cap
Gas Type Marker
(LP Position Shown)
FP1769a
CO137
Minimum
Rate Screw
Fig. 55
Remove rubber cap and adjust gas type marker.