S12800 Routing Switch Installa
tion Manual V1.0
Maipu Confidential & Proprietary Information
Page 55
STATISTICS:
1 IN, 0 OUT, 0 IERR, 0 OERR
System FAN Information(Fan 3 - ONLINE)
----------------------------------------------------------------
Status: Normal
Last-Alarm: Normal
Serial No.:
Description:
Fan-RT-Information:
Fan-speed:47(PWM)
----------------------------------------------------------------
STATISTICS:
1 IN, 0 OUT, 0 IERR, 0 OERR
Table 4-2 Key field description of the information displayed via show system fan
Field
Description
System Fan Information (Fan 0 - ONLINE)
Fan online information, such as Fan 0 - ONLINE
Status
Fan work status, such as Normal
Normal: The fan module works normally
Abnormal: The fan module works abnormally
Last-Alarm
Fan alarm information, such as Normal
Normal: The fan has no alarm information
Abnormal: The fan has alarm information
Serial No.
The serial number of the fan module
Description
The description information field, configured by the
user
Fan-RT-Information
Fan regulating speed information
Fan-speed
Fan speed (the speed indicates the percentage of
the PWM signals actually output by the fan
controller)
4.3.4 View Power Module Status Information
You can use the show system power command to view the information of the power module
used on S12800, including the online information of the power module, work status of the
power module, swapping times of the power module and the error swapping times. For
example:
switch#show system power
System Power Information(Power 0 - ONLINE)
----------------------------------------------------------------
Status: Normal
Last-Alarm: Normal
Description: N/A
----------------------------------------------------------------
STATISTICS:
1 IN, 0 OUT, 0 IERR, 0 OERR