29
Kleiss MCS7-2PVC System Manual
|
www.MainlineControlSystems.com
Attach plugging handle.
Verify drilling dome bleed valve is closed.
Install the dome onto the slide gate valve and
tighten the dome by hand.
While doing so, make certain the plugging spindle
is at the top of the dome. Keep control of the
spindle.
Open the slide gate valve.
With the plugging handle and your hand to
support it, push the plugging spindle fully
downwards.
Screw the plug into the fitting with the plugging
handle until bottomed-out and tight.
Test to make sure there is a seal by opening the
bleed valve on the dome and relieving the pressure
in the dome.