Vacuum Batch Dryer

 - VBD-1000

 

Touchscreen Controller 

VBD-1000

 

Vacuum Batch Dryer

 

 

Touch Screen Controller      

 

INSTALLATION 

 OPERATION 

  MAINTENANCE    

 

 
 

 

 

Rev. March 5, 2018 

Copyright 

 Maguire Products, Inc. 2018 

Содержание VBD-1000

Страница 1: ...RE PRODUCTS INC Vacuum Batch Dryer VBD 1000 Touchscreen Controller VBD 1000 VacuumBatchDryer Touch Screen Controller INSTALLATION OPERATION MAINTENANCE Rev March 5 2018 Copyright Maguire Products Inc...

Страница 2: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 2 VBD Vacuum Dryer...

Страница 3: ...s recommended to read thoroughly these operating instructions Maguire Products Inc accepts no responsibility or liability for damage or malfunction of the equipment arising from non observance of thes...

Страница 4: ...red corrections or provide you with accurate information Additionally we will gladly provide you with an updated copy of any manuals you need at any time We welcome comments and suggestions on ways we...

Страница 5: ...23 Start Up and Operation Instructions 23 What is happening when the Dryer is Running 25 Shutdown Immediate or Planned 26 Recommended Drying Temperatures 29 Maintenance 53 Drain and purge Air Filter R...

Страница 6: ...ther warranties expressed or implied and of all other obligations or liabilities on our part and MAGUIRE PRODUCTS neither assumes nor authorizes any other persons to assume for it any other liability...

Страница 7: ...an reach 350F 180C Typically these surfaces are not at dangerous temperatures however all hot surfaces should be avoided Warning Label indicate HOT SURFACES USE CAUTION when removing and installing ca...

Страница 8: ...at elevates the Retention Hopper Assembly 16 inch allowing material to be convey from the base of the VBD Dryer Weight of the Base Frame is 1303 lb 591 kg Other smaller components will be included An...

Страница 9: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 9 VBD Vacuum Dryer Overall layout and Dimensions...

Страница 10: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 10 VBD Vacuum Dryer...

Страница 11: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 11 VBD Vacuum Dryer...

Страница 12: ...000 will be install on can support the weight of the VBD at 4 corners If the floor cannot support this weight in 4 small footprints use leveling shims on the frame not the leveling feet When adjusting...

Страница 13: ...eating Hopper on top of section B of the VBD dryer Position the Hopper so that the front hatch faces the same side of the dryer as the VBD s control panel Install the 10 1 2 13 grade 8 bolts and tight...

Страница 14: ...g up slide the Upper Vacuum Gate assembly into the slot on the mount ring as shown in the photo to the right Slide the Upper Vacuum Gate onto the mount ring until it fully seats into the slot It may b...

Страница 15: ...w Continue turning until the Vacuum Chamber hanger is lifted 1 4 inch 6mm off of the sliding rail Lifting bolt 1 4 6mm gap Engage load cell Retention Hopper Load Cell Pair The Retention Hopper load ce...

Страница 16: ...ht through the enclosure using the predrilled slotted keyholes in the top panel To install remove the top panel and locate the air lines and RTD thermometer cables On each air line and wire is a rubbe...

Страница 17: ...band Secure the Heating Hopper Inlet RTD thermometer to the side heat inlet of the heating hopper Secure the cable to frame of the heating hopper Route the longer RTD thermometer cable up to the exha...

Страница 18: ...Hopper Heater connected to blower outlet Power Junction Box Plug Purge Air Solenoid Valve Electrical Plug Electrical Field Joints Color Coded inch Purge Line 5 32 inch air lines Install the Heating H...

Страница 19: ...our air supply has oil in it add an oil separator coalescing filter Oil in the air will combine with dust drawn from the vacuum tank forming a paste inside the vacuum generator It will stop working an...

Страница 20: ...and 3 The fourth wire is a green yellow wire and is the ground wire Connect power to a properly fused disconnect See page 81 for the High Voltage Wiring Diagram THREE PHASE 60 cycle 480 volts or 50 c...

Страница 21: ...opper Air Inlet Temperature Actual T2 Dry Purge Air Temperature T2s Dry Purge Air Temperature Setting T2a Dry Purge Air Temperature Actual T3 Heating Hopper Air Outlet Temperature T3s Heating Hopper A...

Страница 22: ...rrent operating mode date and time Ethernet and USB status Navigation Menu Located along the right side of the screen these buttons allow quick navigation to frequently used and top level screens The...

Страница 23: ...lear of all material from all tanks heating hopper Vacuum Chamber and Retention Hopper To facilitate a Clean Out use the Clean Out function accessible from the home screen Startup and Operation Instru...

Страница 24: ...is 20 minutes In the vast majority of drying operations this time is adequate and does not need to be adjusted Special circumstances may require different vacuum times Please consult a Maguire Dryer T...

Страница 25: ...cle begins concurrent to vacuum cycle the first vacuum cycle is timed The new batch of material in the upper portion of the heating hopper will take less time to heat Minimum time in the heating is di...

Страница 26: ...perature of the material in the heating hopper to the specified temperature Cooldown Temp over the specified time period Cooldown Time To adjust the Cooldown Temperature and Cooldown Time use the arro...

Страница 27: ...default 22222 Then press Press Dryer Configuration Display will show the Dryer Configuration categories Press Auto Stop Setup Display will show the Auto Stop screen To Enable Auto Stop Press Auto Stop...

Страница 28: ...temperature Fill Info The desired weight of material to be dispensed into the Vacuum Chamber Bulk Density Bulk density of material in either pounds per cubic foot or kilograms per liter Cycle Count T...

Страница 29: ...orm Extrusion 0 005 150 180 300 350 PMMA Acrylic 0 02 0 04 79 175 POM Acetal 0 20 0 10 80 110 180 230 PPO 0 02 100 120 210 250 PPS 0 02 150 300 PUR 0 02 125 140 260 280 PSU 0 02 150 300 SAN 0 20 0 10...

Страница 30: ...cell Setup Loadcell calibration zero and full calibration Parameters Operation Parameters Blower BDT Blower Delay Time Seconds BLF VFD Low Limit BHF VFD High Limit BDF VFD Frequency BZL VFD Zero Leve...

Страница 31: ...Alarm optional HHL Heating Hopper Low Level Load Cell KDF Loadcell Stable Wt LST Load Cell Stable Time LCZ Loadcell Zero WST Weight Settle Time LZ1 Loadcell 1 Zero LZ2 Loadcell 2 Zero Vacuum VTS Vacu...

Страница 32: ...Maguire Products Inc for updates Factory Access Factory Access Only Restore Parameters Restores factory default parameters Preferences Change Passwords Change Admin and Operator passwords Display Opti...

Страница 33: ...generator Holds the vacuum on the vacuum chamber Vac Cham Purge OPEN CLOSED Located below the vacuum generator When open the vacuum on the vacuum chamber is released Blower Test Operates the blower B...

Страница 34: ...est Operates heater and blower that supplies heat to the Heating Hopper T1s Heating Hopper inlet temp setpoint T1a Heating Hopper inlet temp actual Start Starts the heater test Blower will run during...

Страница 35: ...specific settings such as Alarm Setup Auto Stop Setup Dry Purge Setup Preheat Setup Auto Start Setup Convey Setup Load Cell Setup and Parameters System Configuration includes system wide general sett...

Страница 36: ...al Temp alarm is enabled during any instance where the Heating Hopper is called upon to dispense material into the vacuum chamber and the T2 heating hopper exit temperature is below the ESM parameter...

Страница 37: ...nd vacuum chamber Dump retries Print Alarm Log Prints the Alarm Log See page 67 Clear Alarm Log Clears the Alarm Log See page 67 Auto Start Setup Auto Starts the Dryer at a specified Time and Day s Ca...

Страница 38: ...preheat time Parameters Parameters access See page 41 System Configuration Print Options Print Setup See page 67 Print Parameters Prints the parameter list to a USB Print Alarm History Prints the Ala...

Страница 39: ...ion displays specific system related information about the controller and Dryer Load Cell Diagnostics Displays Vacuum Chamber and Retention Hopper loadcell diagnostics information Alarm and Event Log...

Страница 40: ...uum Dryer Factory Access For factory access only Restore All Restores Factory Defaults WARNING Only do a Restore All when directed by a Maguire Technician Restore Parameters Resets parameters back to...

Страница 41: ...ative BHT VFD Heat Throttle UT1 PD Loop Update Time Dispensing Parameters OT1 Heat1 Over Target Alarm VCH Vac Chamber Hi Level NH1 Heat1 No Heat Alarm VCL Vacuum Chamber Low Level SO1 Heat1 Set Point...

Страница 42: ...may be set to from the Blower Setup menu The maximum settable value for this parameter is 000060 BLF VFD Low Limit Hz 00025 The minimum VFD frequency in Hz that the blower may be set to from the Blow...

Страница 43: ...ning will be triggered when the amount of material is at or above this level When in Auto Cycle the amount of material in the Retention Hopper must be at or below this level in order for the Vacuum Ch...

Страница 44: ...cuum Dump Threshold grams second 00115 During a Vacuum Chamber dump into the Retention Hopper the material flow rate is constantly calculated When the flow rate reaches VTT indicating that the chamber...

Страница 45: ...centage that the Heating Hopper Level Alarm will trigger if enabled in the Alarm Setup menu Any heating hopper level at or below this level will trigger the alarm Heater Parameters PTS Heat1 Temperatu...

Страница 46: ...fter the heat cycle begins during which one of the following two conditions must be detected Either the temperature must climb 20 degrees or the temperature must move at least 20 percent toward the ta...

Страница 47: ...that raw loadcell counts must remain within KDF to produce a stable loadcell reading LCZ Loadcell Zero counts 01000 Minimal allowable counts when zeroing load cells WST Weight Settle Time seconds 000...

Страница 48: ...continues to attempt to pull a target vacuum pressure after alarm sounds NVT No Vacuum Timeout retries time in seconds 00345 The first three digits are the number of retries that the vacuum gates wil...

Страница 49: ...onfiguration Display will show the Dryer Configuration categories Press Parameters Display will show the categories of Parameters Parameters are divided into 6 categories Blower Heater System Dispensi...

Страница 50: ...To enable and run the dryer in Batch Mode follow these steps from the Home Screen Press Start Batch Start Batch button is located on the Home Screen after Batch Mode is enabled Display will show Batc...

Страница 51: ...cations Display will show the System Communications categories Press MLAN I D Number Display will show the MLAN I D Number screen On this screen enter the new ID number using the keypad Valid I D numb...

Страница 52: ...or a password default 22222 Then press Press Display will show the System Configuration categories Press Communications Display will show the System Communications categories Press Modbus Server Displ...

Страница 53: ...m the ambient air supply and protect the heating components of the Dryer The air filter must be periodically checked and cleaned Recommended cleaning interval is monthly More frequent in very dusty en...

Страница 54: ...ation screen Press ZERO Display will say Confirm Vacuum Chamber is empty then press ZERO Gram weight of 0 follows successful calibration Press To return to the Load Cell Setup screen Press Retention H...

Страница 55: ...al from the Heating Hopper to the Vacuum Chamber prior to entering the Full Calibration Routine If material totals are being observed loadcell full weigh calibration is recommended periodically approx...

Страница 56: ...and then properly re install the Vacuum Chamber into the Dryer Press CONTINUE to proceed Wait while calibrating load cells Do not touch weigh bin during calibration After Full calibration has proceede...

Страница 57: ...he Heating Hopper is non removable Prior to opening the front access door removal of all material is recommended Material in the Heating Hopper can be evacuated using the Heating Hopper Manual Drain V...

Страница 58: ...us window will appear Press to return to the Home Screen Clean Out Dump All Dump All opens all valves allowing material to flow freely through the dryer Material in the Heating Hopper will pass into t...

Страница 59: ...To remove the hatch insert rotate the two butterfly latches and then unhook from the hatch faceplate Using two hands slide the hatch insert out of the Vacuum Chamber Use caution handling the Vacuum C...

Страница 60: ...Skirt Raising the skirt requires two people Locate the two skirt handles Using the lift handles raise the skirt up and secure the skirt on the two Skirt Hangers Locate the black lift handle and raise...

Страница 61: ...ure If neither condition is met the NO HEAT alarm will sound Such an occurrence would signal a failure of either the heater or the airflow from the blower This parameter and consequent alarm protects...

Страница 62: ...ts the purge heater from burn out in the event the compressed air failure or airflow is blocked Solution Check compressed airflow to the purge heater is adequate Check that the air line that supplies...

Страница 63: ...Hopper or faulty loadcells Solution If Retention Hopper is missing replace Retention Hopper If Retention Hopper is in place ensure the tank is empty and zero calibrate the load cells If load cells ar...

Страница 64: ...inless steel purge heater tube Press the red reset button to reset the thermal safety switch If problem occurs repeatedly contact Maguire Technical Support VC MISSING ALARM 18 Problem The Vacuum Chamb...

Страница 65: ...essel Fill Adjust and pertains to filling the Vacuum Chamber The VFA parameter is a two part parameter The first three digits are the number of retries to fill the Vacuum Chamber default 3 retries Las...

Страница 66: ...cleared There are two main purposes of this alarm 1 To alert the operator that dry material is ready for the process 2 To act as a hold back when necessary giving the operator additional time to prep...

Страница 67: ...drive Print Event and Alarms A combination of machine status lines at defined intervals as well as mechanical events as they occur Print Alarm History Prints to USB any alarms recorded since the alar...

Страница 68: ...per Loadcell Reading weight in lbs or kgs 18 THROUGHPUT 0 Throughput lbs or kgs hour Example of a VBD Event Log VBD Event Log MODEL 1000 CPU Firmware N0819B I O Firmware N0819B Serial 000000 00 08 20...

Страница 69: ...i Level RHH 00375 00375 00000 00385 Weight D4 Ret Hop Low Level RHL 00025 00025 00000 00227 Weight D5 Bulk Density BLK 00035 00035 00000 65535 Weight D6 Vac Cham Fill Rate VFR 12000 12000 02500 15000...

Страница 70: ...65535 Minutes Load Cell L1 Loadcell Stable Wt KDF 00200 00006 00000 65535 Number L2 Loadcell Stable Time LST 00100 00100 00000 65535 Millisec L3 Loadcell Zero LCZ 01000 01000 00000 65535 Number L4 Wei...

Страница 71: ...el Sensor Off Loader 1 Off Loader 2 Off Loader 2 Mode Thruput Purge Chamber On Admin Settings Blower VFD T4 On T5 Off LOADCELL CALIBRATION NAME ZERO DELTA FULL LAST ZERO LAST FULL RH LC 3303829 158857...

Страница 72: ...re User Settings Save User Settings Press Save User Settings Display will prompt for confirmation to save user settings Press To save the user settings including parameters or press the red X to cance...

Страница 73: ...o refresh the display window Highlight the version in the white panel on the left and press PROGRAM Press To proceed with the firmware update or press the red X to cancel and exit The display will sho...

Страница 74: ...n Large Access Door 18 x 18 Diffuser cone removable without tools 304 Stainless steel internal wall construction material contact VACUUM CHAMBER Capacity 400 lb 180 kg Rail mounted for ease of access...

Страница 75: ...ry Purge inlet Vacuum Vessel Material exit Retention Hopper DRY AIR PURGE CIRCUIT Air filter regulator Coalescing Filter 1 10th micron for removal of oil and fine particulates Exhaust Shut off Compres...

Страница 76: ...vel 78 db A 78 db A 14 primary heater power 35000 watts 35000 watts 15 purge heater power 2000 watts 2000 watts 16 maximum run temperature 375 F 190 C 17 vacuum generator model Xi 3 stage PIAB Xi 3 st...

Страница 77: ...rmance is determined by the moisture content of the resin after the dryer has done its job Resin moisture content however is not easily measured so dryer manufactures use other criteria to assure perf...

Страница 78: ...ability under this warranty will extend only to equipment that is returned to our factory in Aston Pennsylvania PREPAID Please note that we always strive to satisfy our customers in whatever manner is...

Страница 79: ...electrical cabinet 14 eg 60C3 circuit breaker 60 amp C trip 3 pole electrical cabinet 15 es3RT2016 motor contactor 3 pole 20A 24 VDC electrical cabinet 16 esCGC32D motor contactor 3 pole 50A 24 VDC e...

Страница 80: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 80 VBD Vacuum Dryer Wiring Diagrams Low Voltage Wiring Diagram...

Страница 81: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 81 VBD Vacuum Dryer High Voltage Wiring Diagrams...

Страница 82: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 82 VBD Vacuum Dryer...

Страница 83: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 83 VBD Vacuum Dryer...

Страница 84: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 84 VBD Vacuum Dryer...

Страница 85: ...Tel 610 459 4300 Fax 610 459 2700 Email info maguire com Web www maguire com Maguire Europe Tame Park Tamworth Staffordshire B775DY UK Tel 44 1827 265 850 Fax 44 1827 265 855 Email info maguire europ...

Отзывы: