Maguire Products, Inc.
Rev. December 18, 2019
– ULTRA-1000 Touchscreen
40
ULTRA By Maguire
- Ultra Low Energy Dryer
Parameters
All Maguire ULTRA controllers operate according to certain internal PARAMETERS. Because customer
requirements vary widely, we have made parameters accessible for change through the keypad. In most cases,
these parameters will never need to be changed. Some parameters that are routinely adjusted values are
adjustable from the main display. To access and edit the parameters, see
Changing Parameters
in this section:
Changing parameters can have an impact on the Dryers performance. It is highly
recommended that a supervisor change the default Program Mode password to protect the
values. Prior to making any changes, make sure you understand what you are doing. If in
doubt contact a Maguire Dryer Technician before making changes to your dryer.
Blower Parameters:
Heater Parameters:
BDT
Blower Delay Time
PTS
Preheat Temperature Setting
BLF
VFD Low Limit
PHT
Preheat Time
BHF
VFD High Limit
PHD
Preheat Differential
BDF
VFD Frequency
PTD
Preheat Target Delta
BZL
VFD Zero Level
RTS
Run Temperature Set-Point
BLA
VFD Level Adjustment
PT1
PD Loop Proportional
BHT
VFD Heat Throttle
DT1
PD Loop Derivative
BMW
Blower Max Wattage
UT1
PD Loop Update Time
Dispensing Parameters:
OT1
Heat1 Over-Target Alarm
VCH
Vac. Chamber Hi Level
NH1
Heat1 No Heat Alarm
VCL
Vacuum Chamber Low Level
SO1
Heat1 Set-Point Off. Percent
RHH
Ret. Hopper Hi Level
MP1
Heat1 Max Percent
RHL
Retention Hopper Low Level
RO1
Heat1 Restart Offset
BLK
Bulk Density
MAX
Max Temp Set-Point
VFR
Vacuum Chamber Fill Rate
ESL
Energy Savings Limit
VDR
Vacuum Chamber Dump Rate
ESD
E.S. Differential
VFT
Chamber Fill Time
EST
Energy Savings Time
VDT
Chamber Dump Time
ESP
ES Proportioning
FLA
Fill Lag Time
RMP
Temperature Ramp Settings
DLA
Dump Lag Time
CTM
Cool-Down Temperature
VGD
Vacuum Gate Delay
CTR
Cool-Down Timer
VFA
Chamber Fill Adjust
H1W
Heater 1 Max Wattage
HDD
Heating Hopper Dump Delay
PGS
Heat2 Temp Set-Point
VCT
Vacuum Chamber Dump Threshold
PT2
Heat2 Proportional
CDR
Chamber Dump Reties
DT2
Heat2 Derivative
RAL
Residence Alarm
UT2
Heat2 Update Time
BCH
Batch Size
OT2
Heat2 OverTarg Alarm
LTP
Loader Trip Point
NH2
Heat2 No Heat Alarm
LTC
Loader Throughput Cutoff
SO2
Heat2 Set-Point Off.
HHV
Heating Hopper Volume
FO2
Heat2 Fixed Output
HHU
Heating Hopper High Level
DPD
Dry Purge Delay
HLA
Heating Hopper Level Alarm
PST
Purge and Shutdown
L1T
Loader 1 Timings
H2W
Heater 2 Max Wattage
L1A
Loader 1 Alarm
Load Cell Parameters:
L2T
Loader 2 Timings
KDF
Loadcell Stable Wt.
L2A
Loader 2 Alarm
LST
Load Cell Stable Time
Vacuum Parameters:
LCZ
Loadcell Zero
VTS
Vacuum Time Setting
WST
Weight Settle Time
VPL
Vacuum Pressure Low
LZ1
Loadcell 1 Zero
VPD
Vacuum Pressure Delta
LZ2
Loadcell 2 Zero
VSO
Vacuum Shutdown Offset
System Parameters:
LVT
Low Vacuum Timeout
ELT
Event Logging Time
NVT
No Vacuum Timeout
EUS
Energy Usage Setting
VPT
Chamber Purge Timer
VPI
Chamber Purge Interval
ATM
Atmospheric Pressure
Содержание ULTRA-1000
Страница 10: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 10 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 11: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 11 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 89: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 89 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 90: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 90 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 91: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 91 ULTRA By Maguire Ultra Low Energy Dryer...