ULTRA By Maguire
- Ultra Low Energy Dryer
Modes of Operation
Three modes of operation (on Home Screen):
Run Dryer
,
Manual Operations, Clean Out
.
Run Dryer -
See Operation on page 23.
Manual Operations
– Options that allow direct control over specific outputs.
Operate Outputs
Alarm Audio
–
OFF/ON
– Operates audible alarm.
Alarm Strobe
–
OFF/ON
– Operates strobe.
Dry Purge Supply
–
CLOSED/OPEN of dry purge supply air valve
Vac Gate Upper
–
OPEN/CLOSED
– Material gate above vacuum chamber.
Vac Gate Lower
–
OPEN/CLOSED
– visible disk shaped gate below vacuum
chamber.
Vac Cham Fill
–
OPEN/CLOSED - Gate located at the base of the heating
hopper.
Vac Cham Dump
–
OPEN/CLOSED
– Internal gate (not visible) located at the
base of the vacuum chamber.
Vac Gen Supply
–
OPEN/CLOSED
– Vacuum generator supply. When
operating, the vacuum generator supply pulls a vacuum on the vacuum chamber.
Vac Gen Check
–
OPEN/CLOSED
– Vacuum generator check valve located on
the vacuum generator. Holds the vacuum on the vacuum chamber.
Vac Cham Purge
–
OPEN/CLOSED
– Located
below the vacuum generator.
When open the vacuum on the vacuum chamber is released.
Blower Test
–
Operates the blower.
Blower:
OFF/ON toggle using ENTER button.
Aux:
OFF/ON toggle using ENTER button.
Fail Safe:
OFF/ON toggle using ENTER button.
T1s:
Heating Hopper inlet temp setpoint.
T1a:
Heating Hopper inlet temp actual.
Vacuum Test -
Tests the Vacuum System
Vac:
Vacuum pressure readout
Start Test:
Starts the vacuum test. Runs the vacuum generator system.
Evac Time:
Amount of time in minutes/seconds to attain the vacuum setpoint
during the current test.
Cycle:
Amount of time in minutes/seconds between vacuum generator runs
during a vacuum hold. Used to determine vacuum chamber seal integrity.
Pset:
Absolute pressure that the Vacuum Chamber will be evacuated to. See
VPL parameter.
Pdel:
The pressure difference above VPL at while the vacuum generator turns
back on. See VPD parameter.
Purge Cham:
OFF/CYC/ON
Vacuum Chamber Timed Dispense
–
Opens valves for specified milliseconds.
Fill:
Fill Time of the Vacuum Chamber in milliseconds.
Dump:
Dump time of the Vacuum Chamber in milliseconds.
Содержание ULTRA-1000
Страница 10: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 10 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 11: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 11 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 89: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 89 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 90: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 90 ULTRA By Maguire Ultra Low Energy Dryer...
Страница 91: ...Maguire Products Inc Rev December 18 2019 ULTRA 1000 Touchscreen 91 ULTRA By Maguire Ultra Low Energy Dryer...