4 - Command Set
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 68 of 247 (
D998200136-31
)
4.3.17
Command 0x12 - Request Cardholder Signature (SC-S Only | SC-F Only)
This command directs the device to request the cardholder’s signature in the screen shown below:
Figure 4-8 - DynaPro Go Signature Capture Screen
If an error occurs, the device terminates the command and reports the error in ACKSTS of
. For a full list of error codes, see
If no error occurs, the device sends
Report 0x28 - Signature Capture State Report
Table 4-22 - Usage Table for Command 0x12
Bit
7
6
5
4
3
2
1
0
Byte 0
0x12
Byte 1
Wait Time in seconds, (0x01..0xFF; 0x00 = 256 seconds)
Byte 2
Options:
0x00 = Timeout clears any signature data
0x01 = Timeout returns timeout status plus length collected. Sig Data can be requested.
Byte 3
Beeper Behavior (Optional. Only changes device behavior if
Beeper Mode
=
Enabled
in
Command 0x09 - Set / Get Device Configuration
on page