4 - Command Set
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 54 of 247 (
D998200136-31
)
Table 4-10 - Usage Table for Command 0x09 (Set mode) / Response for Command 0x09 (Get mode)
Bit
7
6
5
4
3
2
1
0
Byte 0
0x09
Byte 1
Device Control (default value = 0x00)
Bit 0 Require Mutual Authentication:
0 = No
1 = Yes
Bit 1 MSR Encryption Variant:
0 = PIN
1 = DATA
Bit 2 Reserved
Bit 3 Clear Text Cardholder Data (Clear Text User Data Only)
Enables
Command 0x1F - Request Clear Text Cardholder Data Entry (Clear Text User
and clear text transmission in
Report 0x21 - Cardholder Data Entry Response
0 = Disable
1 = Enable
Bit 4 Reserved
Bit 4 Beeper Mode (Beeper Control Only)
Configure audio feedback
0 = Enable
1 = Disable
Bit 5 Reserved
Bit 6 Bitmap Lock (Bitmaps Only):
0 = Unlocked
1 = Locked
Bit 7 Configuration Lock (NOTE: After locking, unlocking can only be performed by the
manufacturer):
0 = Unlocked
1 = Locked